PURPOSE: To assess the reliability of velocities recorded with the GymAware linear position transducer (LTP) during the squat and bench press exercises. METHODS: Thirteen resistance-trained men (age: 21.7±0.4 years; height 1.74±0.07 m; mass: 82.9±9.5 kg; 1-repetition maximum (1RM) back squat: 149.9±20.7 kg; bench 1RM: 114.8±18.5 kg.) performed three trials of squat and bench press using the following percentages of 1RM: 20, 30, 40, 50, 60, 70, 80%. The order of the loads was counterbalanced across the participants. The mean vertical velocity of the barbell during the concentric phase of each repetition was recorded using a 3-D motion analysis system (Vicon; 200 Hz) and the GymAware LTP. Reliability of the GymAware was determined using intraclass correlations (ICC) and coefficients of variance (CV%). RESULTS: The GymAware showed high intersession reliability for both exercises with ICCs ranging from good to excellent (squat: 0.71-0.91; bench press: 0.83-0.91). CV% showed precision in the recorded velocities during both exercises (squat: 3.6%-5.8%; bench press: 4.9%-7.4%). CONCLUSION: The GymAware LTP shows high intersession reliability for recorded velocities during the squat and bench press exercises.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
PURPOSE: To assess the reliability of velocities recorded with the GymAware linear position transducer (LTP) during the squat and bench press exercises. METHODS: Thirteen resistance-trained men (age: 21.7±0.4 years; height 1.74±0.07 m; mass: 82.9±9.5 kg; 1-repetition maximum (1RM) back squat: 149.9±20.7 kg; bench 1RM: 114.8±18.5 kg.) performed three trials of squat and bench press using the following percentages of 1RM: 20, 30, 40, 50, 60, 70, 80%. The order of the loads was counterbalanced across the participants. The mean vertical velocity of the barbell during the concentric phase of each repetition was recorded using a 3-D motion analysis system (Vicon; 200 Hz) and the GymAware LTP. Reliability of the GymAware was determined using intraclass correlations (ICC) and coefficients of variance (CV%). RESULTS: The GymAware showed high intersession reliability for both exercises with ICCs ranging from good to excellent (squat: 0.71-0.91; bench press: 0.83-0.91). CV% showed precision in the recorded velocities during both exercises (squat: 3.6%-5.8%; bench press: 4.9%-7.4%). CONCLUSION: The GymAware LTP shows high intersession reliability for recorded velocities during the squat and bench press exercises.
Key concepts: Squat, Bench press, One-repetition maximum, Mathematics, Reliability (semiconductor), Concentric, Resistance training, Physical therapy