2005•Indian Journal of Pharmaceutical SciencesRequires access

Stability Indicating RP-HPLC Method For Determination Of Pioglitazone From Tablets

D. B Wanjari, Naresh J. Gaikwad

Open publisher page 9 citations

Abstract

A stability indicating simple, rapid and precise reversed-phase HPLC method has been developed for the quantitation of pioglitazone in tablet on a Hypersil C-8 (250x4.6 mm) column using a mobile phase consisting acetonitrile:0.15% v/v triethylamine (40:60 v/v) adjusted to pH 4.6 with orthophosphoric acid at a flow rate of 1.5 ml/min and detection at 220 nm. The retention time of pioglitazone have been found to be 7.6 min and recoveries were between 99-101%. Validation of the proposed method also been done.

About this research paper

What this paper is about

A stability indicating simple, rapid and precise reversed-phase HPLC method has been developed for the quantitation of pioglitazone in tablet on a Hypersil C-8 (250x4.6 mm) column using a mobile phase consisting acetonitrile:0.15% v/v triethylamine (40:60 v/v) adjusted to pH 4.6 with orthophosphoric acid at a flow rate of 1.5 ml/min and detection at 220 nm. The retention time of pioglitazone have been found to be 7.6 min and recoveries were between 99-101%. Validation of the proposed method also been done.

Why it matters

OpenAlex reports 9 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A stability indicating simple, rapid and precise reversed-phase HPLC method has been developed for the quantitation of pioglitazone in tablet on a Hypersil C-8 (250x4.6 mm) column using a mobile phase consisting acetonitrile:0.15% v/v triethylamine (40:60 v/v) adjusted to pH 4.6 with orthophosphoric acid at a flow rate of 1.5 ml/min and detection at 220 nm. The retention time of pioglitazone have been found to be 7.6 min and recoveries were between 99-101%. Validation of the proposed method also been done.

Key concepts: Pioglitazone, Triethylamine, Chromatography, High-performance liquid chromatography, Chemistry, Acetonitrile, Retention time, Medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
Stability Indicating RP-HPLC Method For Determination Of Pioglitazone From Tablets — Research Paper | ScholarLens