The effects of suxamethonium and pancuronium on the haemodynamic response to endotracheal intubation.

F A Khan, Kamal Rs

Open full text 1 citations

Abstract

The pharmacological effects of suxamethonium and pancuronium on the cardiovascular system may vary and therefore alter the haemodynamic response to intubation. The arterial blood pressure, the heart rate and the rate pressure product were measured as parameters of haemodynamic change in forty adult ASA. I and II patients undergoing laryngoscopy and endotracheal intubation in a randomised controlled study. The patients were induced with either thiopentone/suxamethonium (Group A) or thiopentone/pancuronium (Group B). There was no significant difference between the groups on comparison of systolic and diastolic blood pressure changes. Pancuronium, however, caused a significantly higher rise in the heart rate after endotracheal intubation compared to suxamethonium. In both groups the maximum rate pressure product occurred one minute after intubation, rising by 56% in the suxamethonium group and 64% in the pancuronium group compared to control values. In conclusion, there were significant and statistically similar increases in systolic and diastolic blood pressures and rate pressure product following intubation in both groups with values significantly above baseline until three minutes post intubation but the increase in heart rate in group A was significantly less than that in group B.

Open-access reader

About this research paper

What this paper is about

The pharmacological effects of suxamethonium and pancuronium on the cardiovascular system may vary and therefore alter the haemodynamic response to intubation. The arterial blood pressure, the heart rate and the rate pressure product were measured as parameters of haemodynamic change in forty adult ASA. I and II patients undergoing laryngoscopy and endotracheal intubation in a randomised controlled study. The patients were induced with either thiopentone/suxamethonium (Group A) or thiopentone/pancuronium (Group B). There was no significant difference between the groups on comparison of systolic and diastolic blood pressure changes. Pancuronium, however, caused a significantly higher rise in the heart rate after endotracheal intubation compared to suxamethonium. In both groups the maximum rate pressure product occurred one minute after intubation, rising by 56% in the suxamethonium group and 64% in the pancuronium group compared to control values. In conclusion, there were significant and statistically similar increases in systolic and diastolic blood pressures and rate pressure product following intubation in both groups with values significantly above baseline until three minutes post intubation but the increase in heart rate in group A was significantly less than that in group B.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The pharmacological effects of suxamethonium and pancuronium on the cardiovascular system may vary and therefore alter the haemodynamic response to intubation. The arterial blood pressure, the heart rate and the rate pressure product were measured as parameters of haemodynamic change in forty adult ASA. I and II patients undergoing laryngoscopy and endotracheal intubation in a randomised controlled study. The patients were induced with either thiopentone/suxamethonium (Group A) or thiopentone/pancuronium (Group B). There was no significant difference between the groups on comparison of systolic and diastolic blood pressure changes. Pancuronium, however, caused a significantly higher rise in the heart rate after endotracheal intubation compared to suxamethonium. In both groups the maximum rate pressure product occurred one minute after intubation, rising by 56% in the suxamethonium group and 64% in the pancuronium group compared to control values. In conclusion, there were significant and statistically similar increases in systolic and diastolic blood pressures and rate pressure product following intubation in both groups with values significantly above baseline until three minutes post intubation but the increase in heart rate in group A was significantly less than that in group B.

Key concepts: Medicine, Intubation, Anesthesia, Heart rate, Blood pressure, Hemodynamics, Laryngoscopy, Rate pressure product

Related papers

Back to paper searchBrowse research topicsOriginal source
The effects of suxamethonium and pancuronium on the haemodynamic response to endotracheal intubation. — Research Paper | ScholarLens