1990American Journal of Enology and ViticultureRequires access

Determination of Metallic Cations in Wines by Flow Injection Analysis

José L. F. C. Lima, António O.S.S. Rangel

Open publisher page 18 citations

Abstract

Four flow-injection manifolds were developed aiming to automate the determination of metallic cations (Na, K, Ca, Mg, Fe, Mn, Zn, and Cu) in wines using atomic absorption (AAS) and flame emission (FES) spectrometry as detection processes. Good agreement was obtained between the results of FIA methods and by the reference methods, in which samples are prepared in a discrete manner and then introduced into the detection system. The FIA methods developed present good quality results (relative standard deviation between 0.57% and 1.4%) with high sampling rates (180 to 360 samples per hour) and a low reagent consumption.

About this research paper

What this paper is about

Four flow-injection manifolds were developed aiming to automate the determination of metallic cations (Na, K, Ca, Mg, Fe, Mn, Zn, and Cu) in wines using atomic absorption (AAS) and flame emission (FES) spectrometry as detection processes. Good agreement was obtained between the results of FIA methods and by the reference methods, in which samples are prepared in a discrete manner and then introduced into the detection system. The FIA methods developed present good quality results (relative standard deviation between 0.57% and 1.4%) with high sampling rates (180 to 360 samples per hour) and a low reagent consumption.

Why it matters

OpenAlex reports 18 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Four flow-injection manifolds were developed aiming to automate the determination of metallic cations (Na, K, Ca, Mg, Fe, Mn, Zn, and Cu) in wines using atomic absorption (AAS) and flame emission (FES) spectrometry as detection processes. Good agreement was obtained between the results of FIA methods and by the reference methods, in which samples are prepared in a discrete manner and then introduced into the detection system. The FIA methods developed present good quality results (relative standard deviation between 0.57% and 1.4%) with high sampling rates (180 to 360 samples per hour) and a low reagent consumption.

Key concepts: Reagent, Relative standard deviation, Flow injection analysis, Chemistry, Analytical Chemistry (journal), Metal, Atomic absorption spectroscopy, Sampling (signal processing)

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Metallic Cations in Wines by Flow Injection Analysis — Research Paper | ScholarLens