THE CONTINUOUS MEASUREMENT OF THERMAL-NEUTRON FLUX INTENSITY IN HIGH-POWER NUCLEAR REACTORS
W.R. Loosemore, J.A. Dennis
Abstract
W.R. Loosemore, J.A. Dennis
Abstract
The problem of measuring continuously the thermalneutron flux intensity in high-power reactors at temperatures up to 500 deg C is considered, and it is concluded that the mean-current ionization chamber provides the best solution. The development of a suitable chamber is described, which is made from stainless steel and has a gas filling of xenon. When the electrodes are coated with uranium oxide (U/sub 3/O/sub 8/) containing 0.48 mg of U/sup 235/, the current sensitivity i s 7 x 10/sup -17/ amp/n/cm/sup 2//sec, and at a neutron flux intensity of 10/sup 13/ n/cmsup 2//sec the equillbrium residual current measured in a graphite-moderated reactor is 0.6% of the total output. Life tests were carried out successfully to a total neutron dose of 3 x 10sup 20/ n/cm/sup 2/. At a flux intensity of 10/sup 14/ n/cm/sup 2/ /sec a chamber with uncoated titanium electrodes has the same fraction of residual current as one containing U/ sup 235/, and is preferred as it is not subject to depletion effects. (auth)
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
The problem of measuring continuously the thermalneutron flux intensity in high-power reactors at temperatures up to 500 deg C is considered, and it is concluded that the mean-current ionization chamber provides the best solution. The development of a suitable chamber is described, which is made from stainless steel and has a gas filling of xenon. When the electrodes are coated with uranium oxide (U/sub 3/O/sub 8/) containing 0.48 mg of U/sup 235/, the current sensitivity i s 7 x 10/sup -17/ amp/n/cm/sup 2//sec, and at a neutron flux intensity of 10/sup 13/ n/cmsup 2//sec the equillbrium residual current measured in a graphite-moderated reactor is 0.6% of the total output. Life tests were carried out successfully to a total neutron dose of 3 x 10sup 20/ n/cm/sup 2/. At a flux intensity of 10/sup 14/ n/cm/sup 2/ /sec a chamber with uncoated titanium electrodes has the same fraction of residual current as one containing U/ sup 235/, and is preferred as it is not subject to depletion effects. (auth)
Key concepts: Neutron flux, Xenon, Ionization chamber, Analytical Chemistry (journal), Intensity (physics), Radiochemistry, Materials science, Flux (metallurgy)