A simple, precise, rapid and accurate reverse phase HPLC method developed for the estimation of Telmisartan in tablet dosage form. Luna 5 μ C18, 250 × 4.6 mm, particle size 5 μm, with mobile phase consisting of 5 mM Phosphate buffer: Acetonitrile (60:40, v/v), pH 7.4 was used. The flow rate was 1 ml/min and the effluents were monitored at 295 nm. The retention time was 7.02 min. The detector response was linear in the concentration of 2–14 μg/ml. The respective linear regression equation being Y=61480X-10188. The limit of detection and limit of quantification was 0.06 and 0.18 mcg/ml respectively. The percentage assay of Telmisartan was 100.28 ± 0.93%. The method was validated by determining its accuracy, precision and system suitability. The results of the study showed that the proposed RP-HPLC method is simple, rapid, precise and accurate, which is useful for the routine determination of Telmisartan in bulk drug and in its pharmaceutical dosage form.
OpenAlex reports 4 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
A simple, precise, rapid and accurate reverse phase HPLC method developed for the estimation of Telmisartan in tablet dosage form. Luna 5 μ C18, 250 × 4.6 mm, particle size 5 μm, with mobile phase consisting of 5 mM Phosphate buffer: Acetonitrile (60:40, v/v), pH 7.4 was used. The flow rate was 1 ml/min and the effluents were monitored at 295 nm. The retention time was 7.02 min. The detector response was linear in the concentration of 2–14 μg/ml. The respective linear regression equation being Y=61480X-10188. The limit of detection and limit of quantification was 0.06 and 0.18 mcg/ml respectively. The percentage assay of Telmisartan was 100.28 ± 0.93%. The method was validated by determining its accuracy, precision and system suitability. The results of the study showed that the proposed RP-HPLC method is simple, rapid, precise and accurate, which is useful for the routine determination of Telmisartan in bulk drug and in its pharmaceutical dosage form.
Key concepts: Telmisartan, Chromatography, Dosage form, Detection limit, Chemistry, High-performance liquid chromatography, Particle size, Acetonitrile