2009Asian Journal of Research in ChemistryRequires access

The Estimation of Irinotecan HCl in Parenterals by RP-HPLC.

V Kiran Kumar, N Appala Raju, Namratha Rani, Jvln Seshagiri Rao, T. Satyanarayana

Open publisher page 5 citations

Abstract

A simple, precise, rapid and accurate reverse phase HPLC method developed for the estimation of Irinotecan HCl in tablet dosage form. A X-Terra RP C18, 250x4.6 mm i.d, 5 μm partical size, with mobile phase consisting of Methanol and 0.01 M Ammonium Acetate containing 0.1% formic acid and methanol in the ratio of 50:50 v/v was used. The flow rate was 1 ml/min and the effluents were monitored at 250 nm. The retention time was 4.69 min. The detector response was linear in the concentration of 120–360 mcg/ml. The respective linear regression equation being Y=166582.24x+86439.5. The limit of detection and limit of quantification was 0.06 and 0.18 mcg/ml respectively. The percentage assay of Irinotecan HCl was 99.09%. The method was validated by determining its accuracy, precision and system suitability. The results of the study showed that the proposed RP-HPLC method is simple, rapid, precise and accurate, which is useful for the routine determination of Irinotecan HCl in bulk drug and in its pharmaceutical dosage form.

About this research paper

What this paper is about

A simple, precise, rapid and accurate reverse phase HPLC method developed for the estimation of Irinotecan HCl in tablet dosage form. A X-Terra RP C18, 250x4.6 mm i.d, 5 μm partical size, with mobile phase consisting of Methanol and 0.01 M Ammonium Acetate containing 0.1% formic acid and methanol in the ratio of 50:50 v/v was used. The flow rate was 1 ml/min and the effluents were monitored at 250 nm. The retention time was 4.69 min. The detector response was linear in the concentration of 120–360 mcg/ml. The respective linear regression equation being Y=166582.24x+86439.5. The limit of detection and limit of quantification was 0.06 and 0.18 mcg/ml respectively. The percentage assay of Irinotecan HCl was 99.09%. The method was validated by determining its accuracy, precision and system suitability. The results of the study showed that the proposed RP-HPLC method is simple, rapid, precise and accurate, which is useful for the routine determination of Irinotecan HCl in bulk drug and in its pharmaceutical dosage form.

Why it matters

OpenAlex reports 5 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A simple, precise, rapid and accurate reverse phase HPLC method developed for the estimation of Irinotecan HCl in tablet dosage form. A X-Terra RP C18, 250x4.6 mm i.d, 5 μm partical size, with mobile phase consisting of Methanol and 0.01 M Ammonium Acetate containing 0.1% formic acid and methanol in the ratio of 50:50 v/v was used. The flow rate was 1 ml/min and the effluents were monitored at 250 nm. The retention time was 4.69 min. The detector response was linear in the concentration of 120–360 mcg/ml. The respective linear regression equation being Y=166582.24x+86439.5. The limit of detection and limit of quantification was 0.06 and 0.18 mcg/ml respectively. The percentage assay of Irinotecan HCl was 99.09%. The method was validated by determining its accuracy, precision and system suitability. The results of the study showed that the proposed RP-HPLC method is simple, rapid, precise and accurate, which is useful for the routine determination of Irinotecan HCl in bulk drug and in its pharmaceutical dosage form.

Key concepts: Ammonium acetate, Chromatography, Formic acid, Methanol, Detection limit, Irinotecan, High-performance liquid chromatography, Chemistry

Related papers

Back to paper searchBrowse research topicsOriginal source
The Estimation of Irinotecan HCl in Parenterals by RP-HPLC. — Research Paper | ScholarLens