2012Asian Journal of Research in ChemistryRequires access

Development and Validation of a Stability Indicating RP-HPLC Method for Simultaneous Estimation of Tapentadol and Paracetamol in Bulk and Tablet Dosage Form

D. Thimma Reddy, Manikandan Ramesh, R. Harishchandra Babu, S Ramya, M. Kanaka Durga

Open publisher page 4 citations

Abstract

A simple, selective, and sensitive stability-indicating Reverse phase high performance liquid chromatographic method has been developed and validated for the simultaneous estimation of Paracetamol and Tapentadol in bulk and tablet dosage form. The separation was achieved on a Thermo Hypersil BDS C18, 250 mm × 4.6 mm and 5 μm column with detection of 215nm at 40°c using an isocratic mobile phase mixture of Sodium di hydrogen ortho phosphate (0.1M, pH adjusted to 7 with ortho phosphoric acid) and methanol (60:40 v/v) at flow rate of 0.8 ml/min. The retention times for Paracetamol and Tapentadol were found to be 2.39min and 4.6min respectively with good resolution of 11.32. The method was validated for precision, linearity, accuracy, specificity, LOD, LOQ and Robustness. The calibration curves for Paracetamol and Tapentadol were linear in the concentration range of 325–975 μg/mL, and 50–150 μg/mL respectively. Recoveries for Paracetamol and Tapentadol were found to be in the range of 99% -100% and 100%-102% respectively. Forced degradation studies were performed using acid, base, water and hydrogen peroxide. No interference of the degradation products was detected. As the method is simple, accurate, precise the proposed method can be used for simultaneous estimation of these two drugs in their tablet dosage forms.

About this research paper

What this paper is about

A simple, selective, and sensitive stability-indicating Reverse phase high performance liquid chromatographic method has been developed and validated for the simultaneous estimation of Paracetamol and Tapentadol in bulk and tablet dosage form. The separation was achieved on a Thermo Hypersil BDS C18, 250 mm × 4.6 mm and 5 μm column with detection of 215nm at 40°c using an isocratic mobile phase mixture of Sodium di hydrogen ortho phosphate (0.1M, pH adjusted to 7 with ortho phosphoric acid) and methanol (60:40 v/v) at flow rate of 0.8 ml/min. The retention times for Paracetamol and Tapentadol were found to be 2.39min and 4.6min respectively with good resolution of 11.32. The method was validated for precision, linearity, accuracy, specificity, LOD, LOQ and Robustness. The calibration curves for Paracetamol and Tapentadol were linear in the concentration range of 325–975 μg/mL, and 50–150 μg/mL respectively. Recoveries for Paracetamol and Tapentadol were found to be in the range of 99% -100% and 100%-102% respectively. Forced degradation studies were performed using acid, base, water and hydrogen peroxide. No interference of the degradation products was detected. As the method is simple, accurate, precise the proposed method can be used for simultaneous estimation of these two drugs in their tablet dosage forms.

Why it matters

OpenAlex reports 4 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A simple, selective, and sensitive stability-indicating Reverse phase high performance liquid chromatographic method has been developed and validated for the simultaneous estimation of Paracetamol and Tapentadol in bulk and tablet dosage form. The separation was achieved on a Thermo Hypersil BDS C18, 250 mm × 4.6 mm and 5 μm column with detection of 215nm at 40°c using an isocratic mobile phase mixture of Sodium di hydrogen ortho phosphate (0.1M, pH adjusted to 7 with ortho phosphoric acid) and methanol (60:40 v/v) at flow rate of 0.8 ml/min. The retention times for Paracetamol and Tapentadol were found to be 2.39min and 4.6min respectively with good resolution of 11.32. The method was validated for precision, linearity, accuracy, specificity, LOD, LOQ and Robustness. The calibration curves for Paracetamol and Tapentadol were linear in the concentration range of 325–975 μg/mL, and 50–150 μg/mL respectively. Recoveries for Paracetamol and Tapentadol were found to be in the range of 99% -100% and 100%-102% respectively. Forced degradation studies were performed using acid, base, water and hydrogen peroxide. No interference of the degradation products was detected. As the method is simple, accurate, precise the proposed method can be used for simultaneous estimation of these two drugs in their tablet dosage forms.

Key concepts: Tapentadol, Chromatography, Dosage form, Calibration curve, Phosphoric acid, Methanol, Chemistry, High-performance liquid chromatography

Related papers

Back to paper searchBrowse research topicsOriginal source
Development and Validation of a Stability Indicating RP-HPLC Method for Simultaneous Estimation of Tapentadol and Paracetamol in Bulk and Tablet Dosage Form — Research Paper | ScholarLens