2014Asian Journal of Research in ChemistryRequires access

Development and validation of RP-HPLC method for simultaneous estimation of Tapentadol and Paracetamol in bulk and combined dosage form

Gopalakrishnan Saravanan, Yunoos, Ch. Swapna Latha

Open publisher page 0 citations

Abstract

A simple, rapid, selective, sensitive, linear, precise and accurate RP-HPLC method was developed and validated for the simultaneous estimation of Tapentadol and Paracetamol in pharmaceutical dosage form. Separation was achieved on a reverse phase Hypersil BDS C18 (100 x 4.6 mm, 5 μ particle size) column at ambient temperature using a mobile phase consisting of Methanol: Acetonitrite: Water (50:10:40 v/v/v), at a flow rate of 1.0 ml/min. The UV detection wavelength was 273 nm and 10 μl of sample was injected. The linearity was found to be 10–60 μg/ml for Tapentadol and 65–390 μg/ml for Paracetamol with a correlation coefficient of 0.9992 and 0.9997 respectively. Retention times were found to be 2.96 min and 4.95 min for Tapentadol and Paracetamol respectively. The mean % recoveries were found to be 99.74 ± 0.32% for Tapentadol and 99.88 ± 0.17% for Paracetamol. The method was validated as per the ICH guidelines for sensitivity, linearity, accuracy and precision. The % RSD for precision, robustness and ruggedness of the proposed method was found to be less than 2%. Hence the developed method can be successfully employed for routine quality control analysis of Tapentadol and Paracetamol in pharmaceutical dosage forms.

About this research paper

What this paper is about

A simple, rapid, selective, sensitive, linear, precise and accurate RP-HPLC method was developed and validated for the simultaneous estimation of Tapentadol and Paracetamol in pharmaceutical dosage form. Separation was achieved on a reverse phase Hypersil BDS C18 (100 x 4.6 mm, 5 μ particle size) column at ambient temperature using a mobile phase consisting of Methanol: Acetonitrite: Water (50:10:40 v/v/v), at a flow rate of 1.0 ml/min. The UV detection wavelength was 273 nm and 10 μl of sample was injected. The linearity was found to be 10–60 μg/ml for Tapentadol and 65–390 μg/ml for Paracetamol with a correlation coefficient of 0.9992 and 0.9997 respectively. Retention times were found to be 2.96 min and 4.95 min for Tapentadol and Paracetamol respectively. The mean % recoveries were found to be 99.74 ± 0.32% for Tapentadol and 99.88 ± 0.17% for Paracetamol. The method was validated as per the ICH guidelines for sensitivity, linearity, accuracy and precision. The % RSD for precision, robustness and ruggedness of the proposed method was found to be less than 2%. Hence the developed method can be successfully employed for routine quality control analysis of Tapentadol and Paracetamol in pharmaceutical dosage forms.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A simple, rapid, selective, sensitive, linear, precise and accurate RP-HPLC method was developed and validated for the simultaneous estimation of Tapentadol and Paracetamol in pharmaceutical dosage form. Separation was achieved on a reverse phase Hypersil BDS C18 (100 x 4.6 mm, 5 μ particle size) column at ambient temperature using a mobile phase consisting of Methanol: Acetonitrite: Water (50:10:40 v/v/v), at a flow rate of 1.0 ml/min. The UV detection wavelength was 273 nm and 10 μl of sample was injected. The linearity was found to be 10–60 μg/ml for Tapentadol and 65–390 μg/ml for Paracetamol with a correlation coefficient of 0.9992 and 0.9997 respectively. Retention times were found to be 2.96 min and 4.95 min for Tapentadol and Paracetamol respectively. The mean % recoveries were found to be 99.74 ± 0.32% for Tapentadol and 99.88 ± 0.17% for Paracetamol. The method was validated as per the ICH guidelines for sensitivity, linearity, accuracy and precision. The % RSD for precision, robustness and ruggedness of the proposed method was found to be less than 2%. Hence the developed method can be successfully employed for routine quality control analysis of Tapentadol and Paracetamol in pharmaceutical dosage forms.

Key concepts: Tapentadol, Chromatography, Dosage form, Correlation coefficient, Linearity, High-performance liquid chromatography, Chemistry, Retention time

Related papers

Back to paper searchBrowse research topicsOriginal source
Development and validation of RP-HPLC method for simultaneous estimation of Tapentadol and Paracetamol in bulk and combined dosage form — Research Paper | ScholarLens