1987•Ophthalmic surgery, lasers & imaging retinaRequires access

The Choice of a Syringe For Manual Cortex Aspiration

Hanan Zauberman

Open publisher page 0 citations

Abstract

The friction force of 5-ml, 2-ml, and 1-ml syringes used for manual aspiration of cortex material in extracapsular cataract extraction (ECCE) were compared. It was found that for a 5-ml syringe the force was 500 g, for a 2-ml syringe it was 250 g, and for a 1-ml tuberculin-type syringe it was only 50 g. The ease and duration of cortex aspiration in 30 cases of ECCE were compared using each of the above syringes partially filled with fluid, connected to a 25-gauge Gill's type cannula, and a closed anterior chamber technique. It was found that with the help of a 1-ml tuberculin syringe, cortex material was removed faster and with less finger fatigue than with the 5-ml or 2-ml syringe.

About this research paper

What this paper is about

The friction force of 5-ml, 2-ml, and 1-ml syringes used for manual aspiration of cortex material in extracapsular cataract extraction (ECCE) were compared. It was found that for a 5-ml syringe the force was 500 g, for a 2-ml syringe it was 250 g, and for a 1-ml tuberculin-type syringe it was only 50 g. The ease and duration of cortex aspiration in 30 cases of ECCE were compared using each of the above syringes partially filled with fluid, connected to a 25-gauge Gill's type cannula, and a closed anterior chamber technique. It was found that with the help of a 1-ml tuberculin syringe, cortex material was removed faster and with less finger fatigue than with the 5-ml or 2-ml syringe.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The friction force of 5-ml, 2-ml, and 1-ml syringes used for manual aspiration of cortex material in extracapsular cataract extraction (ECCE) were compared. It was found that for a 5-ml syringe the force was 500 g, for a 2-ml syringe it was 250 g, and for a 1-ml tuberculin-type syringe it was only 50 g. The ease and duration of cortex aspiration in 30 cases of ECCE were compared using each of the above syringes partially filled with fluid, connected to a 25-gauge Gill's type cannula, and a closed anterior chamber technique. It was found that with the help of a 1-ml tuberculin syringe, cortex material was removed faster and with less finger fatigue than with the 5-ml or 2-ml syringe.

Key concepts: Syringe, Cannula, Cortex (anatomy), Medicine, Syringe driver, Surgery, Biology, Psychiatry

Related papers

Back to paper searchBrowse research topicsOriginal source
The Choice of a Syringe For Manual Cortex Aspiration — Research Paper | ScholarLens