Development and Validation of UV Spectrophotometric Method for Estimation of Lurasidone in Bulk and Pharmaceutical Formulations
K. Vijaya Sri, S. Sravani, M. Shiva Kumar
Abstract
K. Vijaya Sri, S. Sravani, M. Shiva Kumar
Abstract
The UV-spectroscopic method were developed and validated for the estimation of Lurasidone HCl as per ICH guidelines. A simple, fast, accurate and precise UV-spectroscopy method was developed by using methanol: water (70: 30v/v) and acetonitrile: water (50: 50v/v) was used as the solvent in both methods. The λmax of Lurasidone was found to be 230 nm and it was proved linear in the concentration range of 2.5–15 μg/ml with a correlation coefficient value of 0.999 for both the methods. The accuracy studies of UV-spectroscopy method was performed at three different levels, i.e., 50%, 100%, and 150% and recovery was found to be in the range of 99.2 to 102.4% respectively. The limit of detection (LOD) and limit of quantification (LOQ) were found to be 0.61–0.69 for both UV Method. The % RSD is <2% which indicates the accuracy and precision of the method.
OpenAlex reports 20 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
The UV-spectroscopic method were developed and validated for the estimation of Lurasidone HCl as per ICH guidelines. A simple, fast, accurate and precise UV-spectroscopy method was developed by using methanol: water (70: 30v/v) and acetonitrile: water (50: 50v/v) was used as the solvent in both methods. The λmax of Lurasidone was found to be 230 nm and it was proved linear in the concentration range of 2.5–15 μg/ml with a correlation coefficient value of 0.999 for both the methods. The accuracy studies of UV-spectroscopy method was performed at three different levels, i.e., 50%, 100%, and 150% and recovery was found to be in the range of 99.2 to 102.4% respectively. The limit of detection (LOD) and limit of quantification (LOQ) were found to be 0.61–0.69 for both UV Method. The % RSD is <2% which indicates the accuracy and precision of the method.
Key concepts: Lurasidone, Chromatography, Biomedical engineering, Biochemical engineering, Mathematics, Chemistry, Medicine, Engineering