2015•Biomedical ChromatographyRequires access

Development and validation of SPMMTE HPLC method for analysis of profens from human plasma

Afzal Hussain, Mohamed Fahad Alajmi, Samira Amir, Imran Ali

Open publisher page 9 citations

Abstract

A fast, selective and reproducible solid-phase membrane microtip extraction (SPMMTE) HPLC method has been developed and validated for the analyses of ibuprofen, ketoprofen, and flurbiprofen from human plasma. The analysis was carried out on a C18 (150 × 4.6 mm; 5 μm) column. The mobile phase used was water-acetonitrile (55:45, v/v) adjusted to pH 3.0 using trifluoroacetic acid, at a flow rate 0.5 mL/min with a detection wavelength of 225 nm. The values for the capacity factors for the profen samples ranged from 0.47 to 1.50. The values for the selectivity factor (α) for ketoprofen-flurbiprofen, flurbiprofen-ibuprofen and ibuprofen-ketoprofen combinations from human plasma samples were 1.99, 1.00 and 2.10, respectively. The resolution factors (Rs) for ketoprofen-flurbiprofen, flurbiprofen-ibuprofen and ibuprofen-ketoprofen from plasma samples were 3.00, 1.50 and 4.10, respectively. The percentage recoveries of ibuprofen, ketoprofen, and flurbiprofen from human plasma were 75-85%. All of the profens were separated within 7.0 min, indicating a relatively fast method. During the development of the SPMMTE procedure the parameters of pH, contact time, desorption and types of solvents were optimized. The final method was also found to be efficient, effective and inexpensive. Copyright © 2016 John Wiley & Sons, Ltd.

About this research paper

What this paper is about

A fast, selective and reproducible solid-phase membrane microtip extraction (SPMMTE) HPLC method has been developed and validated for the analyses of ibuprofen, ketoprofen, and flurbiprofen from human plasma. The analysis was carried out on a C18 (150 × 4.6 mm; 5 μm) column. The mobile phase used was water-acetonitrile (55:45, v/v) adjusted to pH 3.0 using trifluoroacetic acid, at a flow rate 0.5 mL/min with a detection wavelength of 225 nm. The values for the capacity factors for the profen samples ranged from 0.47 to 1.50. The values for the selectivity factor (α) for ketoprofen-flurbiprofen, flurbiprofen-ibuprofen and ibuprofen-ketoprofen combinations from human plasma samples were 1.99, 1.00 and 2.10, respectively. The resolution factors (Rs) for ketoprofen-flurbiprofen, flurbiprofen-ibuprofen and ibuprofen-ketoprofen from plasma samples were 3.00, 1.50 and 4.10, respectively. The percentage recoveries of ibuprofen, ketoprofen, and flurbiprofen from human plasma were 75-85%. All of the profens were separated within 7.0 min, indicating a relatively fast method. During the development of the SPMMTE procedure the parameters of pH, contact time, desorption and types of solvents were optimized. The final method was also found to be efficient, effective and inexpensive. Copyright © 2016 John Wiley & Sons, Ltd.

Why it matters

OpenAlex reports 9 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A fast, selective and reproducible solid-phase membrane microtip extraction (SPMMTE) HPLC method has been developed and validated for the analyses of ibuprofen, ketoprofen, and flurbiprofen from human plasma. The analysis was carried out on a C18 (150 × 4.6 mm; 5 μm) column. The mobile phase used was water-acetonitrile (55:45, v/v) adjusted to pH 3.0 using trifluoroacetic acid, at a flow rate 0.5 mL/min with a detection wavelength of 225 nm. The values for the capacity factors for the profen samples ranged from 0.47 to 1.50. The values for the selectivity factor (α) for ketoprofen-flurbiprofen, flurbiprofen-ibuprofen and ibuprofen-ketoprofen combinations from human plasma samples were 1.99, 1.00 and 2.10, respectively. The resolution factors (Rs) for ketoprofen-flurbiprofen, flurbiprofen-ibuprofen and ibuprofen-ketoprofen from plasma samples were 3.00, 1.50 and 4.10, respectively. The percentage recoveries of ibuprofen, ketoprofen, and flurbiprofen from human plasma were 75-85%. All of the profens were separated within 7.0 min, indicating a relatively fast method. During the development of the SPMMTE procedure the parameters of pH, contact time, desorption and types of solvents were optimized. The final method was also found to be efficient, effective and inexpensive. Copyright © 2016 John Wiley & Sons, Ltd.

Key concepts: Flurbiprofen, Ketoprofen, Chemistry, Chromatography, Ibuprofen, Human plasma, High-performance liquid chromatography, Pharmacology

Related papers

Back to paper searchBrowse research topicsOriginal source
Development and validation of SPMMTE HPLC method for analysis of profens from human plasma — Research Paper | ScholarLens