1999•PubMedRequires access

Simultaneous determination of retinol and α-tocopherol by high pressure liquid chromatography in micro-volumes of serum.

E‐Siong Tee, S C Khor

Open publisher page 11 citations

Abstract

The lack of biochemical data to indicate the prevalence of marginal vitamin A deficiency (VAD) in the country is largely because of the difficulty of obtaining enough serum for analysis, especially from malnourished children. Efforts were therefore made to establish a high-pressure liquid chromatography system (HPLC) for the determination of retinol in micro-volumes of serum. Since our previous studies showed that tocopherol could be simultaneously determined in the same system, studies have been carried out for the determination of both vitamins using retinol acetate and -tocopherol acetate as internal standards. Trials were carried out to determine the most suitable sample treatment procedures and chromatographic system including composition of the mobile phase for handling 20 ml of serum. The HPLC system proposed enables successful separation and quantitation of retinol and α-tocopherol and their respective internal standards, retinol acetate and -tocopherol in less than 14 minutes. Reproducibility studies carried out with pooled sera showed a within day and between day variation of less than 8% and 13% respectively for retinol, whilst variations for α-tocopherol were higher, ranging from 8-16%. The proposed method is currently being applied to the determination of retinol and α-tocopherol in a group of malnourished children under six years of age.

About this research paper

What this paper is about

The lack of biochemical data to indicate the prevalence of marginal vitamin A deficiency (VAD) in the country is largely because of the difficulty of obtaining enough serum for analysis, especially from malnourished children. Efforts were therefore made to establish a high-pressure liquid chromatography system (HPLC) for the determination of retinol in micro-volumes of serum. Since our previous studies showed that tocopherol could be simultaneously determined in the same system, studies have been carried out for the determination of both vitamins using retinol acetate and -tocopherol acetate as internal standards. Trials were carried out to determine the most suitable sample treatment procedures and chromatographic system including composition of the mobile phase for handling 20 ml of serum. The HPLC system proposed enables successful separation and quantitation of retinol and α-tocopherol and their respective internal standards, retinol acetate and -tocopherol in less than 14 minutes. Reproducibility studies carried out with pooled sera showed a within day and between day variation of less than 8% and 13% respectively for retinol, whilst variations for α-tocopherol were higher, ranging from 8-16%. The proposed method is currently being applied to the determination of retinol and α-tocopherol in a group of malnourished children under six years of age.

Why it matters

OpenAlex reports 11 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The lack of biochemical data to indicate the prevalence of marginal vitamin A deficiency (VAD) in the country is largely because of the difficulty of obtaining enough serum for analysis, especially from malnourished children. Efforts were therefore made to establish a high-pressure liquid chromatography system (HPLC) for the determination of retinol in micro-volumes of serum. Since our previous studies showed that tocopherol could be simultaneously determined in the same system, studies have been carried out for the determination of both vitamins using retinol acetate and -tocopherol acetate as internal standards. Trials were carried out to determine the most suitable sample treatment procedures and chromatographic system including composition of the mobile phase for handling 20 ml of serum. The HPLC system proposed enables successful separation and quantitation of retinol and α-tocopherol and their respective internal standards, retinol acetate and -tocopherol in less than 14 minutes. Reproducibility studies carried out with pooled sera showed a within day and between day variation of less than 8% and 13% respectively for retinol, whilst variations for α-tocopherol were higher, ranging from 8-16%. The proposed method is currently being applied to the determination of retinol and α-tocopherol in a group of malnourished children under six years of age.

Key concepts: Retinol, Tocopherol, Chromatography, High-performance liquid chromatography, Vitamin, Retinyl acetate, Chemistry, Vitamin E

Related papers

Back to paper searchBrowse research topicsOriginal source
Simultaneous determination of retinol and α-tocopherol by high pressure liquid chromatography in micro-volumes of serum. — Research Paper | ScholarLens