2014•Journal of Separation ScienceRequires access

Fast, simple, and sensitive high‐performance liquid chromatography method for measuring vitamins A and E in human blood plasma

Chao Yuan, Maria Burgyan, Dustin R. Bunch, Edmunds Z. Reineks, Raymond D. Jackson, Roxanne Steinle, Sihe Wang

Open publisher page 24 citations

Abstract

Vitamins A and E are fat-soluble vitamins that play important roles in several physiological processes. Monitoring their concentrations is needed to detect deficiency and guide therapy. In this study, we developed a high-performance liquid chromatography method to measure the major forms of vitamin A (retinol) and vitamin E (α-tocopherol and γ-tocopherol) in human blood plasma. Vitamins A and E were extracted with hexane and separated on a reversed-phase column using methanol as the mobile phase. Retinol was detected by ultraviolet absorption, whereas tocopherols were detected by fluorescence emission. The chromatographic cycle time was 4.0 min per sample. The analytical measurement range was 0.03-5.14, 0.32-36.02, and 0.10-9.99 mg/L for retinol, α-tocopherol, and γ-tocopherol, respectively. Intr-aassay and total coefficient of variation were <6.0% for all compounds. This method was traceable to standard reference materials offered by the National Institute of Standards and Technology. Reference intervals were established using plasma samples collected from 51 healthy adult donors and were found to be 0.30-1.20, 6.0-23.0, and 0.3-3.2 mg/L for retinol, α-tocopherol, and γ-tocopherol, respectively. In conclusion, we developed and validated a fast, simple, and sensitive high-performance liquid chromatography method for measuring the major forms of vitamins A and E in human plasma.

About this research paper

What this paper is about

Vitamins A and E are fat-soluble vitamins that play important roles in several physiological processes. Monitoring their concentrations is needed to detect deficiency and guide therapy. In this study, we developed a high-performance liquid chromatography method to measure the major forms of vitamin A (retinol) and vitamin E (α-tocopherol and γ-tocopherol) in human blood plasma. Vitamins A and E were extracted with hexane and separated on a reversed-phase column using methanol as the mobile phase. Retinol was detected by ultraviolet absorption, whereas tocopherols were detected by fluorescence emission. The chromatographic cycle time was 4.0 min per sample. The analytical measurement range was 0.03-5.14, 0.32-36.02, and 0.10-9.99 mg/L for retinol, α-tocopherol, and γ-tocopherol, respectively. Intr-aassay and total coefficient of variation were <6.0% for all compounds. This method was traceable to standard reference materials offered by the National Institute of Standards and Technology. Reference intervals were established using plasma samples collected from 51 healthy adult donors and were found to be 0.30-1.20, 6.0-23.0, and 0.3-3.2 mg/L for retinol, α-tocopherol, and γ-tocopherol, respectively. In conclusion, we developed and validated a fast, simple, and sensitive high-performance liquid chromatography method for measuring the major forms of vitamins A and E in human plasma.

Why it matters

OpenAlex reports 24 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Vitamins A and E are fat-soluble vitamins that play important roles in several physiological processes. Monitoring their concentrations is needed to detect deficiency and guide therapy. In this study, we developed a high-performance liquid chromatography method to measure the major forms of vitamin A (retinol) and vitamin E (α-tocopherol and γ-tocopherol) in human blood plasma. Vitamins A and E were extracted with hexane and separated on a reversed-phase column using methanol as the mobile phase. Retinol was detected by ultraviolet absorption, whereas tocopherols were detected by fluorescence emission. The chromatographic cycle time was 4.0 min per sample. The analytical measurement range was 0.03-5.14, 0.32-36.02, and 0.10-9.99 mg/L for retinol, α-tocopherol, and γ-tocopherol, respectively. Intr-aassay and total coefficient of variation were <6.0% for all compounds. This method was traceable to standard reference materials offered by the National Institute of Standards and Technology. Reference intervals were established using plasma samples collected from 51 healthy adult donors and were found to be 0.30-1.20, 6.0-23.0, and 0.3-3.2 mg/L for retinol, α-tocopherol, and γ-tocopherol, respectively. In conclusion, we developed and validated a fast, simple, and sensitive high-performance liquid chromatography method for measuring the major forms of vitamins A and E in human plasma.

Key concepts: High-performance liquid chromatography, Chromatography, Retinol, Tocopherol, Chemistry, Vitamin E, Fat-Soluble Vitamin, Vitamin

Related papers

Back to paper searchBrowse research topicsOriginal source
Fast, simple, and sensitive high‐performance liquid chromatography method for measuring vitamins A and E in human blood plasma — Research Paper | ScholarLens