Simultaneous stability-indicating HPLC method for the determination of cisapride, methylparaben and propylparaben in oral suspension
Jutima Boonleang, Chanpa Tanthana
Abstract
Jutima Boonleang, Chanpa Tanthana
Abstract
A simultaneous stability-indicating HPLC method for the determination of cisapride, methylparaben and propylparabenin oral suspensions has been developed and validated. Baseline separation was achieved on a C18 column at room temperature(25°C) by gradient elution with mobile phase consisting of solvent A: 10% v/v acetonitrile in 0.13% w/v sodium-1-pentanesulfonate pH 8 and solvent B: acetonitrile. The gradient program was as follows: 0-5 min: 20 to 56% solvent B; 5-7min: 56 to 85% solvent B; 7-10 min: 85% solvent B. The flow rate of mobile phase was 1.2 mL/min. The injection volume was20 L. Detection and peak purity assessments were performed by photo-diode array detector set at 275 nm with scan modein the range of 190-400 nm. The method was selective, accurate and precise. It provided chromatograms with good peak shapeand acceptable resolutions of greater than 4.4 for all analytes including the degradation products formed in oral suspensionsin about 8.5 min. All analyte peaks were pure. The accuracy of all analytes was in the range of 99.20-100.6%. The within-runand between-run relative standard deviations were less than 1.50%. The calibration curves for cisapride, methylparaben, andpropylparaben were linear over the concentration range of 10.0-75.0 g/mL, 8.0-100.0 g/mL, and 0.8-10.0 g/mL, respectivelywith r2 greater than 0.999. This developed method was successfully applied to the stability study of cisapride, methylparabenand propylparaben in oral suspension formulations.
OpenAlex reports 5 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
A simultaneous stability-indicating HPLC method for the determination of cisapride, methylparaben and propylparabenin oral suspensions has been developed and validated. Baseline separation was achieved on a C18 column at room temperature(25°C) by gradient elution with mobile phase consisting of solvent A: 10% v/v acetonitrile in 0.13% w/v sodium-1-pentanesulfonate pH 8 and solvent B: acetonitrile. The gradient program was as follows: 0-5 min: 20 to 56% solvent B; 5-7min: 56 to 85% solvent B; 7-10 min: 85% solvent B. The flow rate of mobile phase was 1.2 mL/min. The injection volume was20 L. Detection and peak purity assessments were performed by photo-diode array detector set at 275 nm with scan modein the range of 190-400 nm. The method was selective, accurate and precise. It provided chromatograms with good peak shapeand acceptable resolutions of greater than 4.4 for all analytes including the degradation products formed in oral suspensionsin about 8.5 min. All analyte peaks were pure. The accuracy of all analytes was in the range of 99.20-100.6%. The within-runand between-run relative standard deviations were less than 1.50%. The calibration curves for cisapride, methylparaben, andpropylparaben were linear over the concentration range of 10.0-75.0 g/mL, 8.0-100.0 g/mL, and 0.8-10.0 g/mL, respectivelywith r2 greater than 0.999. This developed method was successfully applied to the stability study of cisapride, methylparabenand propylparaben in oral suspension formulations.
Key concepts: Methylparaben, Propylparaben, Cisapride, Chromatography, High-performance liquid chromatography, Chemistry, Suspension (topology), Pharmacology