Abstract

A new, simple, specific, sensitive, rapid, accurate and precise RP-HPLC method was developed for the proportioning of the methylparaben and the propylparaben in pharmaceutical formulations as well as the phenol, which is their main degradation product. These parabens are widely used as preservatives in pharmaceutical and cosmetic products. The separation was performed on a C18-column using a mobile phase elution gradient (Acetate buffer 50mM pH 5/Acetonitrile). The detection was performed at a fixed wavelength (l = 271nm), with a flow rate of 1.3 ml/min. The detector response was linear in concentrations ranging from 10 to 60 μg/ml for the methylparaben, from 3 to 15 µg/ml for the propylparaben and from 0.125 to 2.5 µg/ml for the phenol. The intra and inter day variation was found to be less than 2%. The limits of quantification and of detection of the phenol are of 0.1 µg/ml and 0.03 µg/ml, respectively. The recovery ratio was equal to 101.8 % for the methylparaben, 101.2 % for the propylparaben and 98.4 % for the phenol. The proposed method was used to monitor the degradation of the parabens and the production of the phenol in studied solutions.

About this research paper

What this paper is about

A new, simple, specific, sensitive, rapid, accurate and precise RP-HPLC method was developed for the proportioning of the methylparaben and the propylparaben in pharmaceutical formulations as well as the phenol, which is their main degradation product. These parabens are widely used as preservatives in pharmaceutical and cosmetic products. The separation was performed on a C18-column using a mobile phase elution gradient (Acetate buffer 50mM pH 5/Acetonitrile). The detection was performed at a fixed wavelength (l = 271nm), with a flow rate of 1.3 ml/min. The detector response was linear in concentrations ranging from 10 to 60 μg/ml for the methylparaben, from 3 to 15 µg/ml for the propylparaben and from 0.125 to 2.5 µg/ml for the phenol. The intra and inter day variation was found to be less than 2%. The limits of quantification and of detection of the phenol are of 0.1 µg/ml and 0.03 µg/ml, respectively. The recovery ratio was equal to 101.8 % for the methylparaben, 101.2 % for the propylparaben and 98.4 % for the phenol. The proposed method was used to monitor the degradation of the parabens and the production of the phenol in studied solutions.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A new, simple, specific, sensitive, rapid, accurate and precise RP-HPLC method was developed for the proportioning of the methylparaben and the propylparaben in pharmaceutical formulations as well as the phenol, which is their main degradation product. These parabens are widely used as preservatives in pharmaceutical and cosmetic products. The separation was performed on a C18-column using a mobile phase elution gradient (Acetate buffer 50mM pH 5/Acetonitrile). The detection was performed at a fixed wavelength (l = 271nm), with a flow rate of 1.3 ml/min. The detector response was linear in concentrations ranging from 10 to 60 μg/ml for the methylparaben, from 3 to 15 µg/ml for the propylparaben and from 0.125 to 2.5 µg/ml for the phenol. The intra and inter day variation was found to be less than 2%. The limits of quantification and of detection of the phenol are of 0.1 µg/ml and 0.03 µg/ml, respectively. The recovery ratio was equal to 101.8 % for the methylparaben, 101.2 % for the propylparaben and 98.4 % for the phenol. The proposed method was used to monitor the degradation of the parabens and the production of the phenol in studied solutions.

Key concepts: Propylparaben, Methylparaben, Chromatography, Chemistry, Phenol, Preservative, High-performance liquid chromatography, Pharmaceutical formulation

Related papers

Back to paper searchBrowse research topicsOriginal source
Stability study of parabens in pharmaceutical formulations containing Paracetamol or Carbocisteine by high-performance liquid chromtatography — Research Paper | ScholarLens