Two Spectrophotometric and HPLC methods are presented for the simultaneous determination of ranitidine HCl and phenol in pharmaceutical injections. The Spectrophotometric methods include first derivative ( 1 D) ultraviolet spectrophotmetry with zero crossing measurement at 238.6 and 228.1 nm for ranitidine HCl and phenol, respectively and first derivative of the ratio spectra ( 1 DD) with measurement of the amplitude of the peak to-trough at 323.2-328.1 nm and peak to zero at 280.1 nm for ranitidine HCl and phenol, respectively. The HPLC method was developed using C18 column with mobile phase consisting of 35 mM potassium dehydrogenate phosphate of pH 7acetonitrile (78:28 v/v) with UV detection at 215 nm. The proposed methods were successfully applied for the determination of ranitidine HCl and phenol in synthetic mixtures and commercial injections.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Two Spectrophotometric and HPLC methods are presented for the simultaneous determination of ranitidine HCl and phenol in pharmaceutical injections. The Spectrophotometric methods include first derivative ( 1 D) ultraviolet spectrophotmetry with zero crossing measurement at 238.6 and 228.1 nm for ranitidine HCl and phenol, respectively and first derivative of the ratio spectra ( 1 DD) with measurement of the amplitude of the peak to-trough at 323.2-328.1 nm and peak to zero at 280.1 nm for ranitidine HCl and phenol, respectively. The HPLC method was developed using C18 column with mobile phase consisting of 35 mM potassium dehydrogenate phosphate of pH 7acetonitrile (78:28 v/v) with UV detection at 215 nm. The proposed methods were successfully applied for the determination of ranitidine HCl and phenol in synthetic mixtures and commercial injections.
Key concepts: Phenol, Chemistry, Chromatography, High-performance liquid chromatography, Ranitidine, Spectrophotometry, Derivative (finance), Detection limit