2014•Unpublished venueRequires access

A Stability Indicating HPLC Method for the Determination of Amodiquine Hydrochloride

Sandhya Bhimrao Lahane, Uday Arvind Deokate, Rajesh B. Nawale

Open publisher page 1 citations

Abstract

Stability indicating HPLC method has been developed for specific determination of Amodiquine hydrochloride during degradation under acid, alkali, thermal and oxidative stress conditions. Acn: Phosphate buffer pH (5.8) with ortho phosphoric acid (80:20), was used as the mobile phase, at a flow rate of 1 ml/min. A Grace smart C18 column (5µ), 344 mm, 2.6 mm i.d. was used as stationary phase. The retention time was approximately 2.6 min. Linearity range was 10-50 µg/ml. The minimum detection and Quantitation limits were 0.1605 and 0.53 µg/ml respectively. Proposed method was validated for precision, accuracy, ruggedness, robustness and specificity.

About this research paper

What this paper is about

Stability indicating HPLC method has been developed for specific determination of Amodiquine hydrochloride during degradation under acid, alkali, thermal and oxidative stress conditions. Acn: Phosphate buffer pH (5.8) with ortho phosphoric acid (80:20), was used as the mobile phase, at a flow rate of 1 ml/min. A Grace smart C18 column (5µ), 344 mm, 2.6 mm i.d. was used as stationary phase. The retention time was approximately 2.6 min. Linearity range was 10-50 µg/ml. The minimum detection and Quantitation limits were 0.1605 and 0.53 µg/ml respectively. Proposed method was validated for precision, accuracy, ruggedness, robustness and specificity.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Stability indicating HPLC method has been developed for specific determination of Amodiquine hydrochloride during degradation under acid, alkali, thermal and oxidative stress conditions. Acn: Phosphate buffer pH (5.8) with ortho phosphoric acid (80:20), was used as the mobile phase, at a flow rate of 1 ml/min. A Grace smart C18 column (5µ), 344 mm, 2.6 mm i.d. was used as stationary phase. The retention time was approximately 2.6 min. Linearity range was 10-50 µg/ml. The minimum detection and Quantitation limits were 0.1605 and 0.53 µg/ml respectively. Proposed method was validated for precision, accuracy, ruggedness, robustness and specificity.

Key concepts: Chromatography, Phosphoric acid, Chemistry, High-performance liquid chromatography, Phosphate buffered saline, Phosphate, Analytical Chemistry (journal), Biochemistry

Related papers

Back to paper searchBrowse research topicsOriginal source
A Stability Indicating HPLC Method for the Determination of Amodiquine Hydrochloride — Research Paper | ScholarLens