2011Unpublished venueRequires access

Development of UV Spectrophotometric method for the simultaneous estimation of Simvastatine and Ezetimibe in tablet dosage form by simultaneous Equation and Absorbance ratio method.

Varsha Balkrishna Mane, Surekha Babar, Nita Kulkarni

Open publisher page 23 citations

Abstract

versatile, accurate, precise and economic method for simultaneous determination of simvastatin and ezetimibe in fixed dose combination products was developed. The absorbance values at 238.2 nm and 247.6 nm and 243.3nm (isoabsorptive point) were used for the estimation of simvastatin and ezetimibe, respectively without mutual interference. This method obeyed Beer's law in the concentration range of 3-18 μg /ml for simvastatin and 5-30 μg /ml for ezetimibe. The results of analyses have been validated statistically for linearity, accuracy and precision, LOD and LOQ of the proposed method. Keywords: Simvastatin (SMV), Ezetimibe (EZE), methanol, distilled water, Simultaneous equation method, Absorption ratio method.

About this research paper

What this paper is about

versatile, accurate, precise and economic method for simultaneous determination of simvastatin and ezetimibe in fixed dose combination products was developed. The absorbance values at 238.2 nm and 247.6 nm and 243.3nm (isoabsorptive point) were used for the estimation of simvastatin and ezetimibe, respectively without mutual interference. This method obeyed Beer's law in the concentration range of 3-18 μg /ml for simvastatin and 5-30 μg /ml for ezetimibe. The results of analyses have been validated statistically for linearity, accuracy and precision, LOD and LOQ of the proposed method. Keywords: Simvastatin (SMV), Ezetimibe (EZE), methanol, distilled water, Simultaneous equation method, Absorption ratio method.

Why it matters

OpenAlex reports 23 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

versatile, accurate, precise and economic method for simultaneous determination of simvastatin and ezetimibe in fixed dose combination products was developed. The absorbance values at 238.2 nm and 247.6 nm and 243.3nm (isoabsorptive point) were used for the estimation of simvastatin and ezetimibe, respectively without mutual interference. This method obeyed Beer's law in the concentration range of 3-18 μg /ml for simvastatin and 5-30 μg /ml for ezetimibe. The results of analyses have been validated statistically for linearity, accuracy and precision, LOD and LOQ of the proposed method. Keywords: Simvastatin (SMV), Ezetimibe (EZE), methanol, distilled water, Simultaneous equation method, Absorption ratio method.

Key concepts: Ezetimibe, Simvastatin, Absorbance, Chromatography, Distilled water, Chemistry, Dosage form, Mathematics

Related papers

Back to paper searchBrowse research topicsOriginal source
Development of UV Spectrophotometric method for the simultaneous estimation of Simvastatine and Ezetimibe in tablet dosage form by simultaneous Equation and Absorbance ratio method. — Research Paper | ScholarLens