1994European Heart JournalRequires access

The role of elastic recoil after balloon angioplasty of rabbit arteries and its prevention by stent implantation

C. FIEHRLEIN, Marieke Zimmerman, J. Pill, J. Metz, W. KϋBLER, Eberhard von Hodenberg

Open publisher page 26 citations

Abstract

Elastic recoil, neointima formation and vessel narrowing after balloon angioplasty or stent implantation were compared in 17 non-atherosclerotic New Zealand White rabbits. The implantation of a balloon-expandable Palmaz-Schatz stent was performed in one iliac artery and a balloon angioplasty alone was performed in the contralateral artery (n = 34 arteries). Quantitative histomorphometry was performed by a computer-assisted analysis 1 h and 4, 10 and 24 weeks after the initial procedure. The histological appearance of the neointima was similar to that of human restenosis. The amount of the neointima was increased within stented vessels as compared to balloon angioplasty alone (1.0 +/- 0.1 vs 0.4 +/- 0.1 mm2 at 4 weeks, P < 0.001). However, the neointimal lumen narrowing was smaller in the stented vessels due to persistent increase in vessel perimeter as compared to balloon angioplasty alone (16.5 +/- 0.9 vs 34.7 +/- 16.5% lumen narrowing at 4 weeks, P < 0.05). In conclusion, stent implantation enhances neointima formation as compared to angioplasty in non-atherosclerotic rabbits. The prevention of elastic recoil after stent implantation, however, reduces the neointimal lumen narrowing. This study supports clinical observations demonstrating lower restenosis rates after stent implantation compared to standard balloon angioplasty.

About this research paper

What this paper is about

Elastic recoil, neointima formation and vessel narrowing after balloon angioplasty or stent implantation were compared in 17 non-atherosclerotic New Zealand White rabbits. The implantation of a balloon-expandable Palmaz-Schatz stent was performed in one iliac artery and a balloon angioplasty alone was performed in the contralateral artery (n = 34 arteries). Quantitative histomorphometry was performed by a computer-assisted analysis 1 h and 4, 10 and 24 weeks after the initial procedure. The histological appearance of the neointima was similar to that of human restenosis. The amount of the neointima was increased within stented vessels as compared to balloon angioplasty alone (1.0 +/- 0.1 vs 0.4 +/- 0.1 mm2 at 4 weeks, P < 0.001). However, the neointimal lumen narrowing was smaller in the stented vessels due to persistent increase in vessel perimeter as compared to balloon angioplasty alone (16.5 +/- 0.9 vs 34.7 +/- 16.5% lumen narrowing at 4 weeks, P < 0.05). In conclusion, stent implantation enhances neointima formation as compared to angioplasty in non-atherosclerotic rabbits. The prevention of elastic recoil after stent implantation, however, reduces the neointimal lumen narrowing. This study supports clinical observations demonstrating lower restenosis rates after stent implantation compared to standard balloon angioplasty.

Why it matters

OpenAlex reports 26 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Elastic recoil, neointima formation and vessel narrowing after balloon angioplasty or stent implantation were compared in 17 non-atherosclerotic New Zealand White rabbits. The implantation of a balloon-expandable Palmaz-Schatz stent was performed in one iliac artery and a balloon angioplasty alone was performed in the contralateral artery (n = 34 arteries). Quantitative histomorphometry was performed by a computer-assisted analysis 1 h and 4, 10 and 24 weeks after the initial procedure. The histological appearance of the neointima was similar to that of human restenosis. The amount of the neointima was increased within stented vessels as compared to balloon angioplasty alone (1.0 +/- 0.1 vs 0.4 +/- 0.1 mm2 at 4 weeks, P < 0.001). However, the neointimal lumen narrowing was smaller in the stented vessels due to persistent increase in vessel perimeter as compared to balloon angioplasty alone (16.5 +/- 0.9 vs 34.7 +/- 16.5% lumen narrowing at 4 weeks, P < 0.05). In conclusion, stent implantation enhances neointima formation as compared to angioplasty in non-atherosclerotic rabbits. The prevention of elastic recoil after stent implantation, however, reduces the neointimal lumen narrowing. This study supports clinical observations demonstrating lower restenosis rates after stent implantation compared to standard balloon angioplasty.

Key concepts: Neointima, Restenosis, Medicine, Angioplasty, Elastic recoil, Balloon, Lumen (anatomy), Stent

Related papers

Back to paper searchBrowse research topicsOriginal source
The role of elastic recoil after balloon angioplasty of rabbit arteries and its prevention by stent implantation — Research Paper | ScholarLens