1996Microscopy Research and TechniqueRequires access

Cross-sectional sample preparation by focused ion beam: A review of ion-sample interaction

Tohru Ishitani, Toshie Yaguchi

Open publisher page 120 citations

Abstract

A focused ion beam (FIB) was applied for cross-sectional sample preparation with both transmission electron microscopes (TEM) and scanning electron microscopes (SEM). The FIB sample preparation has the advantage of high positioning accuracy for cross sections. On the other hand, a broad ion beam (BIB) has been conventionally used for thinning TEM samples. Although both FIB and BIB use energetic ion beams, they are essentially different from each other in many aspects such as beam size, beam current density, incident angle of the beam with respect to cross sections, and beam scanning (i.e., dynamic or static beam). In this study, FIB cross-sectioning is compared with BIB thinning. We review inherent characteristics such as positioning accuracy and uniformity of cross section, radiation damage, and beam heating. Discussion is held from a view-point of ion beam and sample interaction.

About this research paper

What this paper is about

A focused ion beam (FIB) was applied for cross-sectional sample preparation with both transmission electron microscopes (TEM) and scanning electron microscopes (SEM). The FIB sample preparation has the advantage of high positioning accuracy for cross sections. On the other hand, a broad ion beam (BIB) has been conventionally used for thinning TEM samples. Although both FIB and BIB use energetic ion beams, they are essentially different from each other in many aspects such as beam size, beam current density, incident angle of the beam with respect to cross sections, and beam scanning (i.e., dynamic or static beam). In this study, FIB cross-sectioning is compared with BIB thinning. We review inherent characteristics such as positioning accuracy and uniformity of cross section, radiation damage, and beam heating. Discussion is held from a view-point of ion beam and sample interaction.

Why it matters

OpenAlex reports 120 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A focused ion beam (FIB) was applied for cross-sectional sample preparation with both transmission electron microscopes (TEM) and scanning electron microscopes (SEM). The FIB sample preparation has the advantage of high positioning accuracy for cross sections. On the other hand, a broad ion beam (BIB) has been conventionally used for thinning TEM samples. Although both FIB and BIB use energetic ion beams, they are essentially different from each other in many aspects such as beam size, beam current density, incident angle of the beam with respect to cross sections, and beam scanning (i.e., dynamic or static beam). In this study, FIB cross-sectioning is compared with BIB thinning. We review inherent characteristics such as positioning accuracy and uniformity of cross section, radiation damage, and beam heating. Discussion is held from a view-point of ion beam and sample interaction.

Key concepts: Focused ion beam, Ion beam, Beam (structure), Materials science, Ion, Cross section (physics), Electron beam-induced deposition, Sample (material)

Related papers

Back to paper searchBrowse research topicsOriginal source
Cross-sectional sample preparation by focused ion beam: A review of ion-sample interaction — Research Paper | ScholarLens