Utility of electronystagmography in the prediction of post-operative outcome following cochlear implantation
J. Spitzer, Divya A. Chari, Elizabeth Machmer, Sheli Lipson, Layla Rouse, Anil K. Lalwani
Abstract
J. Spitzer, Divya A. Chari, Elizabeth Machmer, Sheli Lipson, Layla Rouse, Anil K. Lalwani
Abstract
OBJECTIVE: To examine the relationship between pre-operative electronystagmography and videonystagmography test results and post-operative outcomes in dizziness, auditory sensitivity and speech recognition. METHODS: A retrospective chart review was performed. Auditory sensitivity and speech perception ability were tested pre- and post-operatively in 37 adult cochlear implant recipients. Auditory sensitivity was evaluated using either pure tones (for testing with earphones) or frequency-modulated warble tones (for sound-field testing). Speech perception ability was evaluated using Northwestern University Auditory Test Number 6. RESULTS: No correlation was found between pre-operative electronystagmography test results and post-operative subjective dizziness. However, pre-operative electronystagmography testing and post-operative hearing sensitivity as measured by warble tone average (dB HL) correlated significantly at six months or later after cochlear implant activation (r ≥ -0.34, n = 34, p < 0.05). CONCLUSION: This study, which has a level of evidence 4, demonstrates that pre-operative electronystagmography testing has a potential use in predicting post-operative outcomes in hearing sensitivity following cochlear implantation. However, larger studies are needed to confirm this novel finding.
OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
OBJECTIVE: To examine the relationship between pre-operative electronystagmography and videonystagmography test results and post-operative outcomes in dizziness, auditory sensitivity and speech recognition. METHODS: A retrospective chart review was performed. Auditory sensitivity and speech perception ability were tested pre- and post-operatively in 37 adult cochlear implant recipients. Auditory sensitivity was evaluated using either pure tones (for testing with earphones) or frequency-modulated warble tones (for sound-field testing). Speech perception ability was evaluated using Northwestern University Auditory Test Number 6. RESULTS: No correlation was found between pre-operative electronystagmography test results and post-operative subjective dizziness. However, pre-operative electronystagmography testing and post-operative hearing sensitivity as measured by warble tone average (dB HL) correlated significantly at six months or later after cochlear implant activation (r ≥ -0.34, n = 34, p < 0.05). CONCLUSION: This study, which has a level of evidence 4, demonstrates that pre-operative electronystagmography testing has a potential use in predicting post-operative outcomes in hearing sensitivity following cochlear implantation. However, larger studies are needed to confirm this novel finding.
Key concepts: Electronystagmography, Audiology, Medicine, Cochlear implant, Speech perception, Perception, Psychology, Nystagmus