Speech-evoked cognitive P300 potentials in cochlear implant recipients.
Alan G. Micco, Nina Kraus, Dawn Burton Koch, Therese McGee, Thomas D. Carrell, Anuradha Sharma, Trent Nicol, Richard J. Wiet
Abstract
Alan G. Micco, Nina Kraus, Dawn Burton Koch, Therese McGee, Thomas D. Carrell, Anuradha Sharma, Trent Nicol, Richard J. Wiet
Abstract
The cognitive P300 evoked potential was elicited by speech stimuli in successful cochlear implant recipients, and the resulting P300 morphology was remarkably similar to that of normal-hearing individuals. The P300 was elicited by the synthesized speech pair/da/and/di/ presented using an oddball paradigm to nine "good" Nucleus cochlear implant users and nine age-matched normal-hearing subjects (34-81 yr old). There were no significant differences in P300 amplitude and latency between the two groups. Moreover, the N1 and P2 potentials occurred at similar latencies in the two groups, although the N1 amplitude was significantly smaller in the cochlear implant users. The P300 was absent in one "poor" cochlear implant user. The results suggest that the P300 may serve as a useful tool for evaluating the cognitive aspects of auditory processing in cochlear implant recipients, and that it may aid in assessing the success of cochlear implantation.
OpenAlex reports 72 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
The cognitive P300 evoked potential was elicited by speech stimuli in successful cochlear implant recipients, and the resulting P300 morphology was remarkably similar to that of normal-hearing individuals. The P300 was elicited by the synthesized speech pair/da/and/di/ presented using an oddball paradigm to nine "good" Nucleus cochlear implant users and nine age-matched normal-hearing subjects (34-81 yr old). There were no significant differences in P300 amplitude and latency between the two groups. Moreover, the N1 and P2 potentials occurred at similar latencies in the two groups, although the N1 amplitude was significantly smaller in the cochlear implant users. The P300 was absent in one "poor" cochlear implant user. The results suggest that the P300 may serve as a useful tool for evaluating the cognitive aspects of auditory processing in cochlear implant recipients, and that it may aid in assessing the success of cochlear implantation.
Key concepts: Cochlear implant, Audiology, Medicine, Implant, Oddball paradigm, Cognition, Latency (audio), Cochlea