Validated liquid chromatographic method for quantitative determination of allicin in garlic powder and tablets
Marta de Diego, Marcia Avello, Sigrid Mennickent, Marcos Fernández, Pola Fernández
Abstract
Marta de Diego, Marcia Avello, Sigrid Mennickent, Marcos Fernández, Pola Fernández
Abstract
In the present study, an RP high performance liquid chromatographic method was developed and validated for the determination of allicin in garlic powder and tablets. Chromatographic separation was carried out on an RP-18(e )column (125 mm x 4 mm), using a mobile phase, consisting of methanol-water (50:50 v/v), at a flow rate of 0.5 mL/min and UV detection at 220 nm. Ethylparaben was used as the internal standard. The assay was linear for allicin concentrations of 5.0-60.0 microg/mL. The RSD for precision was <6.14%. The accuracy was above 89.11%. The detection and quantification limits were 0.27 and 0.81 microg/mL, respectively. This method was used to quantify allicin in garlic powder samples. The results showed that the method described here is useful for the determination of allicin in garlic powder and tablets.
OpenAlex reports 16 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
In the present study, an RP high performance liquid chromatographic method was developed and validated for the determination of allicin in garlic powder and tablets. Chromatographic separation was carried out on an RP-18(e )column (125 mm x 4 mm), using a mobile phase, consisting of methanol-water (50:50 v/v), at a flow rate of 0.5 mL/min and UV detection at 220 nm. Ethylparaben was used as the internal standard. The assay was linear for allicin concentrations of 5.0-60.0 microg/mL. The RSD for precision was <6.14%. The accuracy was above 89.11%. The detection and quantification limits were 0.27 and 0.81 microg/mL, respectively. This method was used to quantify allicin in garlic powder samples. The results showed that the method described here is useful for the determination of allicin in garlic powder and tablets.
Key concepts: Allicin, Chromatography, Chemistry, GARLIC POWDER, Methanol, Detection limit, Quantitative analysis (chemistry), High-performance liquid chromatography