2001•Journal of Clinical MicrobiologyOpen access

Quantitative Detection of Hepatitis B Virus DNA by Real-Time Nucleic Acid Sequence-Based Amplification with Molecular Beacon Detection

Sol Yates, Maarten T. Penning, Jaap Goudsmit, Inge Frantzen, Bert van de Weijer, Dianne van Strijp, Bob van Gemen

Open full text 80 citations

Abstract

We have developed a hepatitis B virus (HBV) DNA detection and quantification system based on amplification with nucleic acid sequence-based amplification (NASBA) technology and real-time detection with molecular beacon technology. NASBA is normally applied to amplify single-stranded target RNA, producing RNA amplicons. In this work we show that with modifications like primer design, sample extraction method, and template denaturation, the NASBA technique can be made suitable for DNA target amplification resulting in RNA amplicons. A major advantage of our assay is the one-tube, isothermal nature of the method, which allows high-throughput applications for nucleic acid detection. The homogeneous real-time detection allows a closed-tube format of the assay, avoiding any postamplification handling of amplified material and therefore minimizing the risk of contamination of subsequent reactions. The assay has a detection range of 10(3) to 10(9) HBV DNA copies/ml of plasma or serum (6 logs), with good reproducibility and precision. Compared with other HBV DNA assays, our assay provides good sensitivity, a wide dynamic range, and high-throughput applicability, making it a viable alternative to those based on other amplification or detection methods.

About this research paper

What this paper is about

We have developed a hepatitis B virus (HBV) DNA detection and quantification system based on amplification with nucleic acid sequence-based amplification (NASBA) technology and real-time detection with molecular beacon technology. NASBA is normally applied to amplify single-stranded target RNA, producing RNA amplicons. In this work we show that with modifications like primer design, sample extraction method, and template denaturation, the NASBA technique can be made suitable for DNA target amplification resulting in RNA amplicons. A major advantage of our assay is the one-tube, isothermal nature of the method, which allows high-throughput applications for nucleic acid detection. The homogeneous real-time detection allows a closed-tube format of the assay, avoiding any postamplification handling of amplified material and therefore minimizing the risk of contamination of subsequent reactions. The assay has a detection range of 10(3) to 10(9) HBV DNA copies/ml of plasma or serum (6 logs), with good reproducibility and precision. Compared with other HBV DNA assays, our assay provides good sensitivity, a wide dynamic range, and high-throughput applicability, making it a viable alternative to those based on other amplification or detection methods.

Why it matters

OpenAlex reports 80 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

We have developed a hepatitis B virus (HBV) DNA detection and quantification system based on amplification with nucleic acid sequence-based amplification (NASBA) technology and real-time detection with molecular beacon technology. NASBA is normally applied to amplify single-stranded target RNA, producing RNA amplicons. In this work we show that with modifications like primer design, sample extraction method, and template denaturation, the NASBA technique can be made suitable for DNA target amplification resulting in RNA amplicons. A major advantage of our assay is the one-tube, isothermal nature of the method, which allows high-throughput applications for nucleic acid detection. The homogeneous real-time detection allows a closed-tube format of the assay, avoiding any postamplification handling of amplified material and therefore minimizing the risk of contamination of subsequent reactions. The assay has a detection range of 10(3) to 10(9) HBV DNA copies/ml of plasma or serum (6 logs), with good reproducibility and precision. Compared with other HBV DNA assays, our assay provides good sensitivity, a wide dynamic range, and high-throughput applicability, making it a viable alternative to those based on other amplification or detection methods.

Key concepts: NASBA, Amplicon, Molecular beacon, Nucleic acid, DNA, Primer (cosmetics), RNA, Biology

Related papers

Back to paper searchBrowse research topicsOriginal source
Quantitative Detection of Hepatitis B Virus DNA by Real-Time Nucleic Acid Sequence-Based Amplification with Molecular Beacon Detection — Research Paper | ScholarLens