1960•IEEE Transactions on Microwave Theory and TechniquesRequires access

A Dielectric Resonator Method of Measuring Inductive Capacities in the Millimeter Range

Basil W. Hakki, Paul D. Coleman

Open publisher page 3,113 citations

Abstract

A novel technique for the measurement of dielectric and magnetic properties of a homogeneous isotropic medium in the range of approximately 3 to 100 kmc is described. An accuracy of /l.chemc/ 1 per cent is possible in the determination of permittivity or permeability in those cases where the loss tangent is sulliciently small. The measuring structure is a resonator made up of a right circular cyndrical dielectric rod placed between two parallel conducting plates. For measurement of permittivity two or more resonant TE/sub onl/ mode frequencies are determined whereas for the measurement of permeability two or more resonant TM/sub onl/ mode frequencies are determined. The dielectric or magnetic properties are computed from the resonance frequencies, structure dimensions, and unloaded Q. Since the loss tangent is inversely proportional to the unloaded Q of the structure, the precision to which Q is measured determines the accuracy of the loss tangent.

About this research paper

What this paper is about

A novel technique for the measurement of dielectric and magnetic properties of a homogeneous isotropic medium in the range of approximately 3 to 100 kmc is described. An accuracy of /l.chemc/ 1 per cent is possible in the determination of permittivity or permeability in those cases where the loss tangent is sulliciently small. The measuring structure is a resonator made up of a right circular cyndrical dielectric rod placed between two parallel conducting plates. For measurement of permittivity two or more resonant TE/sub onl/ mode frequencies are determined whereas for the measurement of permeability two or more resonant TM/sub onl/ mode frequencies are determined. The dielectric or magnetic properties are computed from the resonance frequencies, structure dimensions, and unloaded Q. Since the loss tangent is inversely proportional to the unloaded Q of the structure, the precision to which Q is measured determines the accuracy of the loss tangent.

Why it matters

OpenAlex reports 3113 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A novel technique for the measurement of dielectric and magnetic properties of a homogeneous isotropic medium in the range of approximately 3 to 100 kmc is described. An accuracy of /l.chemc/ 1 per cent is possible in the determination of permittivity or permeability in those cases where the loss tangent is sulliciently small. The measuring structure is a resonator made up of a right circular cyndrical dielectric rod placed between two parallel conducting plates. For measurement of permittivity two or more resonant TE/sub onl/ mode frequencies are determined whereas for the measurement of permeability two or more resonant TM/sub onl/ mode frequencies are determined. The dielectric or magnetic properties are computed from the resonance frequencies, structure dimensions, and unloaded Q. Since the loss tangent is inversely proportional to the unloaded Q of the structure, the precision to which Q is measured determines the accuracy of the loss tangent.

Key concepts: Dissipation factor, Permittivity, Dielectric, Isotropy, Resonator, Materials science, Dielectric loss, Dielectric resonator

Related papers

Back to paper searchBrowse research topicsOriginal source
A Dielectric Resonator Method of Measuring Inductive Capacities in the Millimeter Range — Research Paper | ScholarLens