Wide-dynamic-range fast preamplifier for pulse shape analysis of signals from high-capacitance detectors
Ciro Boiano, R. Bassini, Alberto Pullia, Angelo S. Pagano
Abstract
Ciro Boiano, R. Bassini, Alberto Pullia, Angelo S. Pagano
Abstract
A new hybrid charge-sensitive preamplifier with a sensitivity of 5 mV/MeV has been specifically designed to operate in conjunction with high-capacitance silicon detectors. The shape of the leading edge of its impulse response remains fast (20 ns) and unchanged over the full output voltage range (7 V), as is required in nuclear-physics experiments in which pulse-shape analysis is used for particle identification. The circuit is miniaturized onto two sides of a ceramic substrate as small as 17/spl times/23 mm/sup 2/. A low-noise fast discharge technique is used: the return to the high-value feedback resistor (R/sub F/) comes from a noninverting low-gain (A) amplifier cascaded to the principal charge-amplifier loop. This yields a reduction of the fall time of a factor A, with no changes of C/sub F/ and R/sub F/ and no added noise. The shorter fall time reduces the pileup effects in presence of high event rates. Special care has been devoted to the matching between the high capacitance of the detector and that of the input stage of the preamplifier. To match a high capacitance, four BF862 field-effect transistors have been connected in parallel.
OpenAlex reports 35 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
A new hybrid charge-sensitive preamplifier with a sensitivity of 5 mV/MeV has been specifically designed to operate in conjunction with high-capacitance silicon detectors. The shape of the leading edge of its impulse response remains fast (20 ns) and unchanged over the full output voltage range (7 V), as is required in nuclear-physics experiments in which pulse-shape analysis is used for particle identification. The circuit is miniaturized onto two sides of a ceramic substrate as small as 17/spl times/23 mm/sup 2/. A low-noise fast discharge technique is used: the return to the high-value feedback resistor (R/sub F/) comes from a noninverting low-gain (A) amplifier cascaded to the principal charge-amplifier loop. This yields a reduction of the fall time of a factor A, with no changes of C/sub F/ and R/sub F/ and no added noise. The shorter fall time reduces the pileup effects in presence of high event rates. Special care has been devoted to the matching between the high capacitance of the detector and that of the input stage of the preamplifier. To match a high capacitance, four BF862 field-effect transistors have been connected in parallel.
Key concepts: Preamplifier, Capacitance, Amplifier, Physics, Dynamic range, Noise (video), Transistor, Detector