Saline aerosol bolus dispersion. I. The effect of acinar airway alteration
Sylvia A. B. Verbanck, Daniël Schuermans, Walter Vincken, Manuel Paiva
Abstract
Sylvia A. B. Verbanck, Daniël Schuermans, Walter Vincken, Manuel Paiva
Abstract
We explored the possibility of using a saline aerosol for bolus dispersion measurements to detect peripheral airway alterations in smokers. Indexes of ventilation inhomogeneity in conductive (S(cond)) and acinar (S(acin)) lung zones, as derived from the multiple-breath N(2) washout (Verbanck S, Schuermans D, Van Muylem A, Noppen M, Paiva M, and Vincken W, J Appl Physiol 83: 1807-1816, 1997), were also measured. The saline bolus test consisted of inhaling 60-ml saline aerosol boluses to different volumetric lung depths (VLD) in the 1.1 liter volume above functional residual capacity. In the never-smoker group (n = 12), saline boluses showed bolus dispersion values consistent with normal values reported in the literature for 0.5- to 1-microm aerosols. In the smoker group (n = 12; 28 +/- 9 pack years, mean +/- SD), significant increases were seen on dispersion and skew of the most peripherally inhaled saline boluses (VLD = 800 ml; P < 0.05) as well as on S(acin) (P = 0.007) with respect to never-smokers. Shallow inhaled boluses (VLD = 200 ml) and S(cond) did not reveal any significant differences between smokers and never-smokers. This study shows the consistent response of two conceptually independent tests, in which both saline aerosol and gas-derived indexes point to a heterogeneous distribution of smoking-induced structural alterations in the lung periphery.
OpenAlex reports 15 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
We explored the possibility of using a saline aerosol for bolus dispersion measurements to detect peripheral airway alterations in smokers. Indexes of ventilation inhomogeneity in conductive (S(cond)) and acinar (S(acin)) lung zones, as derived from the multiple-breath N(2) washout (Verbanck S, Schuermans D, Van Muylem A, Noppen M, Paiva M, and Vincken W, J Appl Physiol 83: 1807-1816, 1997), were also measured. The saline bolus test consisted of inhaling 60-ml saline aerosol boluses to different volumetric lung depths (VLD) in the 1.1 liter volume above functional residual capacity. In the never-smoker group (n = 12), saline boluses showed bolus dispersion values consistent with normal values reported in the literature for 0.5- to 1-microm aerosols. In the smoker group (n = 12; 28 +/- 9 pack years, mean +/- SD), significant increases were seen on dispersion and skew of the most peripherally inhaled saline boluses (VLD = 800 ml; P < 0.05) as well as on S(acin) (P = 0.007) with respect to never-smokers. Shallow inhaled boluses (VLD = 200 ml) and S(cond) did not reveal any significant differences between smokers and never-smokers. This study shows the consistent response of two conceptually independent tests, in which both saline aerosol and gas-derived indexes point to a heterogeneous distribution of smoking-induced structural alterations in the lung periphery.
Key concepts: Saline, Bolus (digestion), Anesthesia, Aerosol, Nitrogen washout, Lung volumes, Medicine, Functional residual capacity