Measurement of high lung volumes by nitrogen washout method
Yakov Sivan, Jürg Hammer, Christopher J. L. Newth
Abstract
Yakov Sivan, Jürg Hammer, Christopher J. L. Newth
Abstract
Studies on human infants suggested that thoracic gas volume (TGV) measured at end exhalation may not depict the true TGV and may differ from TGV measured from a series of higher lung volumes and corrected for the volume added. This was explained by gas trapping. If true, we should expect the discrepancy to be more pronounced when functional residual capacity (FRC) and higher lung volumes are measured by gas dilution techniques. We studied lung volumes above FRC by the nitrogen washout technique in 12 spontaneously breathing rhesus monkeys (5.0-11.3 kg wt; 42 compared measurements). Lung volumes directly measured were compared with preset lung volumes achieved by artificial inflation of the lungs above FRC with known volumes of air (100-260 ml). Measured lung volume strongly correlated with and was not significantly different from present lung volume (P = 0.05; r = 0.996). The difference between measured and preset lung volume was 0-5% in 41 of 42 cases [1 +/- 0.4% (SE)]. The direction of the difference was unpredictable; in 22 of 42 cases the measured volume was larger than the preset volume, but in 17 of 42 cases it was smaller. The difference was not affected by the volume of gas artificially inflated into the lungs. We conclude that, overall, lung volumes above FRC can be reliably measured by the nitrogen washout technique and that FRC measurements by this method reasonably reflect true FRC.
OpenAlex reports 13 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Studies on human infants suggested that thoracic gas volume (TGV) measured at end exhalation may not depict the true TGV and may differ from TGV measured from a series of higher lung volumes and corrected for the volume added. This was explained by gas trapping. If true, we should expect the discrepancy to be more pronounced when functional residual capacity (FRC) and higher lung volumes are measured by gas dilution techniques. We studied lung volumes above FRC by the nitrogen washout technique in 12 spontaneously breathing rhesus monkeys (5.0-11.3 kg wt; 42 compared measurements). Lung volumes directly measured were compared with preset lung volumes achieved by artificial inflation of the lungs above FRC with known volumes of air (100-260 ml). Measured lung volume strongly correlated with and was not significantly different from present lung volume (P = 0.05; r = 0.996). The difference between measured and preset lung volume was 0-5% in 41 of 42 cases [1 +/- 0.4% (SE)]. The direction of the difference was unpredictable; in 22 of 42 cases the measured volume was larger than the preset volume, but in 17 of 42 cases it was smaller. The difference was not affected by the volume of gas artificially inflated into the lungs. We conclude that, overall, lung volumes above FRC can be reliably measured by the nitrogen washout technique and that FRC measurements by this method reasonably reflect true FRC.
Key concepts: Nitrogen washout, Functional residual capacity, Lung volumes, Washout, Lung, Exhalation, Volume (thermodynamics), Residual volume