2015IEEE Sensors JournalOpen access

Electrical Capacitance Tomography With Differential Sensor

Ziqiang Cui, Huaxiang Wang, Wuliang Yin

Open full text 42 citations

Abstract

In electrical capacitance tomography, capacitance changes are used to determine the permittivity distribution in the imaging area. However, the changes are small compared with the standing capacitances, e.g., usually in the order of 10%-30%. For a single channel capacitance sensor, a differential configuration having a redundant pair of electrodes can be used to cancel the standing capacitance. However, there has been no report so far introducing such differential configuration into electrical capacitance tomography (ECT) sensors. This is mainly due to the fact that an ECT sensor is composed of an array of electrodes, e.g., 8, 12, and 16 and the capacitance measurements in ECT are required to interrogate capacitances of all electrode pair combinations, which introduce significant difficulty for a differential configuration. In this paper, a novel differential ECT sensor is proposed and designed, which consists of concentrically arranged dual array electrodes. It can also be thought as an additional array of electrodes being inserted between the measuring electrodes and the outer screen of a conventional ECT sensor. The new sensor design has been validated by the numerical simulation. A prototype sensor has been developed and evaluated with an field programmable gate arrays (FPGA)-based ECT measurement system, showing that with the proposed differential sensor, the dynamic range of the measured capacitance is reduced by $\sim 80$ % and an average improvement of 10.8 dB in signal-to-noise ratio is achieved.

About this research paper

What this paper is about

In electrical capacitance tomography, capacitance changes are used to determine the permittivity distribution in the imaging area. However, the changes are small compared with the standing capacitances, e.g., usually in the order of 10%-30%. For a single channel capacitance sensor, a differential configuration having a redundant pair of electrodes can be used to cancel the standing capacitance. However, there has been no report so far introducing such differential configuration into electrical capacitance tomography (ECT) sensors. This is mainly due to the fact that an ECT sensor is composed of an array of electrodes, e.g., 8, 12, and 16 and the capacitance measurements in ECT are required to interrogate capacitances of all electrode pair combinations, which introduce significant difficulty for a differential configuration. In this paper, a novel differential ECT sensor is proposed and designed, which consists of concentrically arranged dual array electrodes. It can also be thought as an additional array of electrodes being inserted between the measuring electrodes and the outer screen of a conventional ECT sensor. The new sensor design has been validated by the numerical simulation. A prototype sensor has been developed and evaluated with an field programmable gate arrays (FPGA)-based ECT measurement system, showing that with the proposed differential sensor, the dynamic range of the measured capacitance is reduced by $\sim 80$ % and an average improvement of 10.8 dB in signal-to-noise ratio is achieved.

Why it matters

OpenAlex reports 42 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In electrical capacitance tomography, capacitance changes are used to determine the permittivity distribution in the imaging area. However, the changes are small compared with the standing capacitances, e.g., usually in the order of 10%-30%. For a single channel capacitance sensor, a differential configuration having a redundant pair of electrodes can be used to cancel the standing capacitance. However, there has been no report so far introducing such differential configuration into electrical capacitance tomography (ECT) sensors. This is mainly due to the fact that an ECT sensor is composed of an array of electrodes, e.g., 8, 12, and 16 and the capacitance measurements in ECT are required to interrogate capacitances of all electrode pair combinations, which introduce significant difficulty for a differential configuration. In this paper, a novel differential ECT sensor is proposed and designed, which consists of concentrically arranged dual array electrodes. It can also be thought as an additional array of electrodes being inserted between the measuring electrodes and the outer screen of a conventional ECT sensor. The new sensor design has been validated by the numerical simulation. A prototype sensor has been developed and evaluated with an field programmable gate arrays (FPGA)-based ECT measurement system, showing that with the proposed differential sensor, the dynamic range of the measured capacitance is reduced by $\sim 80$ % and an average improvement of 10.8 dB in signal-to-noise ratio is achieved.

Key concepts: Capacitance, Electrical capacitance tomography, Differential capacitance, Materials science, Capacitance probe, Electrode, Noise (video), Engine coolant temperature sensor

Related papers

Back to paper searchBrowse research topicsOriginal source
Electrical Capacitance Tomography With Differential Sensor — Research Paper | ScholarLens