1984Medical PhysicsRequires access

Investigation of basic imaging properties in digital radiography. I. Modulation transfer function

Maryellen L. Giger, Kunio Doi

Open publisher page 154 citations

Abstract

The effect of various digital parameters, such as the sampling aperture, sampling distance, and display aperture, on the modulation transfer function (MTF) of digital radiographic imaging systems was investigated by means of theoretical simulation studies. The MTFs were also determined experimentally to confirm the relationship used in the simulation studies. The results indicate that the overall MTF of a digital system cannot specify the resolution properties in the same way as can the MTFs of analog systems. The MTF of a digital system may include a "false" response due to aliasing, which could lead to an incorrect interpretation of the resolution properties. The magnitude of aliasing that will occur in a digitized signal depends on the sampling parameters chosen and on the frequency content of the radiologic object being imaged. Thus, the type of object to be detected as well as various digital parameters must be considered in the design and evaluation of digital imaging systems.

About this research paper

What this paper is about

The effect of various digital parameters, such as the sampling aperture, sampling distance, and display aperture, on the modulation transfer function (MTF) of digital radiographic imaging systems was investigated by means of theoretical simulation studies. The MTFs were also determined experimentally to confirm the relationship used in the simulation studies. The results indicate that the overall MTF of a digital system cannot specify the resolution properties in the same way as can the MTFs of analog systems. The MTF of a digital system may include a "false" response due to aliasing, which could lead to an incorrect interpretation of the resolution properties. The magnitude of aliasing that will occur in a digitized signal depends on the sampling parameters chosen and on the frequency content of the radiologic object being imaged. Thus, the type of object to be detected as well as various digital parameters must be considered in the design and evaluation of digital imaging systems.

Why it matters

OpenAlex reports 154 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The effect of various digital parameters, such as the sampling aperture, sampling distance, and display aperture, on the modulation transfer function (MTF) of digital radiographic imaging systems was investigated by means of theoretical simulation studies. The MTFs were also determined experimentally to confirm the relationship used in the simulation studies. The results indicate that the overall MTF of a digital system cannot specify the resolution properties in the same way as can the MTFs of analog systems. The MTF of a digital system may include a "false" response due to aliasing, which could lead to an incorrect interpretation of the resolution properties. The magnitude of aliasing that will occur in a digitized signal depends on the sampling parameters chosen and on the frequency content of the radiologic object being imaged. Thus, the type of object to be detected as well as various digital parameters must be considered in the design and evaluation of digital imaging systems.

Key concepts: Optical transfer function, Aliasing, Aperture (computer memory), Transfer function, Digital radiography, Sampling (signal processing), Computer science, Digital imaging

Related papers

Back to paper searchBrowse research topicsOriginal source
Investigation of basic imaging properties in digital radiography. I. Modulation transfer function — Research Paper | ScholarLens