HPLC Methods for Determination of Dihydroxyacetone and Glycerol in Fermentation Broth and Comparison with a Visible Spectrophotometric Method to Determine Dihydroxyacetone
Jie Chen, Jie Chen, Chen Zhou, Jie Chen, Chen Zhou
Abstract
Jie Chen, Jie Chen, Chen Zhou, Jie Chen, Chen Zhou
Abstract
High-performance liquid chromatographic (HPLC) methods were respectively developed for the quantitative determination of dihydroxyacetone (DHA) and glycerol in the fermentation broth. Validation parameters such as linearity, precision, accuracy, and specificity, limit of detection (LOD), and limit of quantitation (LOQ) were determined. Both HPLC methods were carried out on a Lichrospher 5-NH2 column with a mobile phase constituted of acetonitrile and water (90:10, v/v). The linearity range for DHA was 2.00-12.00 mg/mL with a correlation coefficient (r) of 0.9994. The LOD and LOQ were 0.06 and 1.20 mg/mL, respectively. The linearity range for glycerol was 0.50-20.00 mg/mL with a correlation coefficient of 0.9998. The LOD and LOQ were 0.22 and 0.50 mg/mL, respectively. Also, the HPLC method to determine DHA was compared with an existing visible spectrophotometric method. Statistical analysis by F-test and t-test showed no significant difference at 95% confidence level between the two methods when applied to low DHA concentrations while a large deviation existed in the determinations of high DHA concentrations. The HPLC method was more accurate to determine high DHA concentrations.
OpenAlex reports 11 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
High-performance liquid chromatographic (HPLC) methods were respectively developed for the quantitative determination of dihydroxyacetone (DHA) and glycerol in the fermentation broth. Validation parameters such as linearity, precision, accuracy, and specificity, limit of detection (LOD), and limit of quantitation (LOQ) were determined. Both HPLC methods were carried out on a Lichrospher 5-NH2 column with a mobile phase constituted of acetonitrile and water (90:10, v/v). The linearity range for DHA was 2.00-12.00 mg/mL with a correlation coefficient (r) of 0.9994. The LOD and LOQ were 0.06 and 1.20 mg/mL, respectively. The linearity range for glycerol was 0.50-20.00 mg/mL with a correlation coefficient of 0.9998. The LOD and LOQ were 0.22 and 0.50 mg/mL, respectively. Also, the HPLC method to determine DHA was compared with an existing visible spectrophotometric method. Statistical analysis by F-test and t-test showed no significant difference at 95% confidence level between the two methods when applied to low DHA concentrations while a large deviation existed in the determinations of high DHA concentrations. The HPLC method was more accurate to determine high DHA concentrations.
Key concepts: Chromatography, Chemistry, Detection limit, Dihydroxyacetone, High-performance liquid chromatography, Correlation coefficient, Acetonitrile, Glycerol