2008ElectrophoresisRequires access

Rapid separation and determination of microcystins using monolithic columns in isocratic elution mode by pressurized capillary electrochromatography

Congying Gu, Li Lin, Bin Li, Xiaodong Chen, Jicun Ren, Jinping Jia, Dan Wu, Nenghu Fang

Open publisher page 9 citations

Abstract

As a new wave of technology, polymethacrylate-based monolithic column was prepared and its application in the separation of three kinds of microcystins (MCs) in pressurized capillary electrochromatography with ultraviolet detection was studied. The key factors affecting the separation performance, such as monolithic column, pressure of the pump, component and concentration of mobile phase and the voltage, were investigated and optimized in detail. A baseline separation could be achieved in less than 6 min using a 5 mM borate buffer with a pH of 9.6 and 10% acetonitrile as the mobile phases in isocratic elution, under a voltage of +13 kV and a supplementary pressure of 7.5 MPa. The calibration curves were linear with correlation coefficient r>0.998 over a range of 0.10-25.00 mg/L. The LODs for the three MCs were in the range of 0.03-0.09 mg/L. This method was successfully applied to separate MCs from other compounds in spiked tap water after solid-phase extraction. The lower LODs for MC-LR, MC-YR and MC-RR were obtained to be 0.10, 0.13, 0.16 microg/L, respectively. These results make it clear that this proposed system is accurate and robust enough to be used as a fast separation tool for routine monitoring of MCs in real water samples.

About this research paper

What this paper is about

As a new wave of technology, polymethacrylate-based monolithic column was prepared and its application in the separation of three kinds of microcystins (MCs) in pressurized capillary electrochromatography with ultraviolet detection was studied. The key factors affecting the separation performance, such as monolithic column, pressure of the pump, component and concentration of mobile phase and the voltage, were investigated and optimized in detail. A baseline separation could be achieved in less than 6 min using a 5 mM borate buffer with a pH of 9.6 and 10% acetonitrile as the mobile phases in isocratic elution, under a voltage of +13 kV and a supplementary pressure of 7.5 MPa. The calibration curves were linear with correlation coefficient r>0.998 over a range of 0.10-25.00 mg/L. The LODs for the three MCs were in the range of 0.03-0.09 mg/L. This method was successfully applied to separate MCs from other compounds in spiked tap water after solid-phase extraction. The lower LODs for MC-LR, MC-YR and MC-RR were obtained to be 0.10, 0.13, 0.16 microg/L, respectively. These results make it clear that this proposed system is accurate and robust enough to be used as a fast separation tool for routine monitoring of MCs in real water samples.

Why it matters

OpenAlex reports 9 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

As a new wave of technology, polymethacrylate-based monolithic column was prepared and its application in the separation of three kinds of microcystins (MCs) in pressurized capillary electrochromatography with ultraviolet detection was studied. The key factors affecting the separation performance, such as monolithic column, pressure of the pump, component and concentration of mobile phase and the voltage, were investigated and optimized in detail. A baseline separation could be achieved in less than 6 min using a 5 mM borate buffer with a pH of 9.6 and 10% acetonitrile as the mobile phases in isocratic elution, under a voltage of +13 kV and a supplementary pressure of 7.5 MPa. The calibration curves were linear with correlation coefficient r>0.998 over a range of 0.10-25.00 mg/L. The LODs for the three MCs were in the range of 0.03-0.09 mg/L. This method was successfully applied to separate MCs from other compounds in spiked tap water after solid-phase extraction. The lower LODs for MC-LR, MC-YR and MC-RR were obtained to be 0.10, 0.13, 0.16 microg/L, respectively. These results make it clear that this proposed system is accurate and robust enough to be used as a fast separation tool for routine monitoring of MCs in real water samples.

Key concepts: Chromatography, Electrochromatography, Capillary electrochromatography, Elution, Calibration curve, Analytical Chemistry (journal), Extraction (chemistry), Monolithic HPLC column

Related papers

Back to paper searchBrowse research topicsOriginal source
Rapid separation and determination of microcystins using monolithic columns in isocratic elution mode by pressurized capillary electrochromatography — Research Paper | ScholarLens