A novel ion-selective membrane electrode for the determination of duloxetine
Reda A.A. Ammar, Haleema Y. Otaif, Abdulrhman Al-Warthan
Abstract
Reda A.A. Ammar, Haleema Y. Otaif, Abdulrhman Al-Warthan
Abstract
A novel duloxetine ion-selective poly(vinyl chloride) membrane electrode based on the ion-pair complex of duloxetine with phosphomolybdic acid was prepared with diocyl phthalate as a plasticizer. The electrode exhibits a linear response with a slope of 56.9 mV decade¬1 of duloxetine concentration at 25 ± 0.1 °C for the optimum electrode prepared with a membrane consisting of 10.0% ion pairs. The electrode response was not sensitive to pH changes from 4.30–8.35 and was not affected by possible interfering species such as common inorganic cations, sugars and amino acids. It has a relatively fast response time less than (15 s) and the lifetime was about 2 months during which it could be used without any measurable divergence. The electrode was successfully used for the potentiometric determination of duloxetine hydrochloride both in pure solutions and in pharmaceutical preparations.
OpenAlex reports 10 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
A novel duloxetine ion-selective poly(vinyl chloride) membrane electrode based on the ion-pair complex of duloxetine with phosphomolybdic acid was prepared with diocyl phthalate as a plasticizer. The electrode exhibits a linear response with a slope of 56.9 mV decade¬1 of duloxetine concentration at 25 ± 0.1 °C for the optimum electrode prepared with a membrane consisting of 10.0% ion pairs. The electrode response was not sensitive to pH changes from 4.30–8.35 and was not affected by possible interfering species such as common inorganic cations, sugars and amino acids. It has a relatively fast response time less than (15 s) and the lifetime was about 2 months during which it could be used without any measurable divergence. The electrode was successfully used for the potentiometric determination of duloxetine hydrochloride both in pure solutions and in pharmaceutical preparations.
Key concepts: Potentiometric titration, Electrode, Chemistry, Membrane, Plasticizer, Ion selective electrode, Duloxetine, Vinyl chloride