2009Journal of Analytical ToxicologyRequires access

Screening, Quantification, and Confirmation of Phenylbutazone and Oxyphenbutazone in Equine Plasma by Liquid Chromatography-Tandem Mass Spectrometry

Youwen You, Cornelius E. Uboh, Lawrence R. Soma, Fuyu Guan, Xiaoqing Li, Jeffrey A. Rudy, Jinwen Chen

Open publisher page 21 citations

Abstract

A sensitive liquid chromatographic-tandem mass spectrometric method was developed and validated for screening, quantification, and confirmation of phenylbutazone and oxyphenbutazone in equine plasma. Analytes were recovered from plasma by liquid-liquid extraction followed by separation in a reversed-phase column and identification by mass spectrometry with selected reaction monitoring in negative electrospray ionization mode. Extraction recovery for both analytes was >80%. Limits of detection, quantification, and confirmation for both analytes were 0.01 microg/mL (S/N>or= 3), 0.05 microg/mL, and 0.05 microg/mL, respectively. The assay with d9-labeled phenylbutazone as internal standard (IS) was linear over a range of 0.05-20 microg/mL (r2>0.995). Intra- and interday precision in terms of coefficient of variation was less than 15%. Intra- and interday accuracy (bias%) was within 80-120%. Hemolysis of red blood cells decreased analyte signal intensity but did not affect quantification results because an isotope-labeled IS was used. Analytes were stable in plasma for 24 h at room temperature, 9 days at 4 degrees C, and 45 days at -20 degrees C and -70 degrees C. The method was successfully used in screening, quantification, and confirmation of phenylbutazone in post-competition plasma samples obtained from racehorses. The method is simple, rapid, and reliably reproducible.

About this research paper

What this paper is about

A sensitive liquid chromatographic-tandem mass spectrometric method was developed and validated for screening, quantification, and confirmation of phenylbutazone and oxyphenbutazone in equine plasma. Analytes were recovered from plasma by liquid-liquid extraction followed by separation in a reversed-phase column and identification by mass spectrometry with selected reaction monitoring in negative electrospray ionization mode. Extraction recovery for both analytes was >80%. Limits of detection, quantification, and confirmation for both analytes were 0.01 microg/mL (S/N>or= 3), 0.05 microg/mL, and 0.05 microg/mL, respectively. The assay with d9-labeled phenylbutazone as internal standard (IS) was linear over a range of 0.05-20 microg/mL (r2>0.995). Intra- and interday precision in terms of coefficient of variation was less than 15%. Intra- and interday accuracy (bias%) was within 80-120%. Hemolysis of red blood cells decreased analyte signal intensity but did not affect quantification results because an isotope-labeled IS was used. Analytes were stable in plasma for 24 h at room temperature, 9 days at 4 degrees C, and 45 days at -20 degrees C and -70 degrees C. The method was successfully used in screening, quantification, and confirmation of phenylbutazone in post-competition plasma samples obtained from racehorses. The method is simple, rapid, and reliably reproducible.

Why it matters

OpenAlex reports 21 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A sensitive liquid chromatographic-tandem mass spectrometric method was developed and validated for screening, quantification, and confirmation of phenylbutazone and oxyphenbutazone in equine plasma. Analytes were recovered from plasma by liquid-liquid extraction followed by separation in a reversed-phase column and identification by mass spectrometry with selected reaction monitoring in negative electrospray ionization mode. Extraction recovery for both analytes was >80%. Limits of detection, quantification, and confirmation for both analytes were 0.01 microg/mL (S/N>or= 3), 0.05 microg/mL, and 0.05 microg/mL, respectively. The assay with d9-labeled phenylbutazone as internal standard (IS) was linear over a range of 0.05-20 microg/mL (r2>0.995). Intra- and interday precision in terms of coefficient of variation was less than 15%. Intra- and interday accuracy (bias%) was within 80-120%. Hemolysis of red blood cells decreased analyte signal intensity but did not affect quantification results because an isotope-labeled IS was used. Analytes were stable in plasma for 24 h at room temperature, 9 days at 4 degrees C, and 45 days at -20 degrees C and -70 degrees C. The method was successfully used in screening, quantification, and confirmation of phenylbutazone in post-competition plasma samples obtained from racehorses. The method is simple, rapid, and reliably reproducible.

Key concepts: Chromatography, Chemistry, Oxyphenbutazone, Analyte, Phenylbutazone, Electrospray ionization, Mass spectrometry, Selected reaction monitoring

Related papers

Back to paper searchBrowse research topicsOriginal source
Screening, Quantification, and Confirmation of Phenylbutazone and Oxyphenbutazone in Equine Plasma by Liquid Chromatography-Tandem Mass Spectrometry — Research Paper | ScholarLens