Orthogonal Signal Correction - Partial Least Squares Method for Simultaneous Spectrophotometric Determination of Nickel, Cobalt, and Zinc
Али Ниази, Amir Azizi
Abstract
Али Ниази, Amir Azizi
Abstract
The simultaneous determination of nickel, cobalt, and zinc mixtures by spectrophotometric method is a difficult problem in analytical chemistry, due to spectral interferences. By multivariate calibration methods, such as partial least squares (PLS) regression, it is possible to obtain a model adjusted to the concentration values of the mixtures used in the calibration range. Orthogonal signal correction (OSC) is a preprocessing technique used for removing the information unrelated to the target variables based on constrained principal component analysis. OSC is a suitable preprocessing method for partial least squares calibration of mixtures without loss of prediction capacity using spectrophotometric method. In this study, the calibration model is based on absorption spectra in the 450-600 nm range for 21 different mixtures of nickel, cobalt, and zinc. Calibration matrices were formed from samples containing 0.025-0.55, 0.025-0.50, and 0.025-0.50 m g mL-1 for nickel, cobalt, and zinc, respectively. The RMSEP for nickel, cobalt, and zinc with OSC and without OSC were 0.0127, 0.0101, and 0.0145, and 0.0045, 0.0049, and 0.0058 m g mL-1, respectively. This procedure allows the simultaneous determination of nickel, cobalt, and zinc in synthetic and real samples and good reliability of the determination was proved.
OpenAlex reports 9 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
The simultaneous determination of nickel, cobalt, and zinc mixtures by spectrophotometric method is a difficult problem in analytical chemistry, due to spectral interferences. By multivariate calibration methods, such as partial least squares (PLS) regression, it is possible to obtain a model adjusted to the concentration values of the mixtures used in the calibration range. Orthogonal signal correction (OSC) is a preprocessing technique used for removing the information unrelated to the target variables based on constrained principal component analysis. OSC is a suitable preprocessing method for partial least squares calibration of mixtures without loss of prediction capacity using spectrophotometric method. In this study, the calibration model is based on absorption spectra in the 450-600 nm range for 21 different mixtures of nickel, cobalt, and zinc. Calibration matrices were formed from samples containing 0.025-0.55, 0.025-0.50, and 0.025-0.50 m g mL-1 for nickel, cobalt, and zinc, respectively. The RMSEP for nickel, cobalt, and zinc with OSC and without OSC were 0.0127, 0.0101, and 0.0145, and 0.0045, 0.0049, and 0.0058 m g mL-1, respectively. This procedure allows the simultaneous determination of nickel, cobalt, and zinc in synthetic and real samples and good reliability of the determination was proved.
Key concepts: Partial least squares regression, Nickel, Cobalt, Zinc, Chemistry, Calibration, Analytical Chemistry (journal), Chromatography