2007Annali di ChimicaRequires access

Spectrophotometric Simultaneous Determination of Manganese(II) and Iron(II) in Pharmaceutical by Orthogonal Signal Correction‐Partial Least Squares

Mohammad Goodarzi, Tahmine Goodarzi, Nahid Ghasemi

Open publisher page 16 citations

Abstract

The simultaneous determination of manganese(II) and iron(II) mixtures by using spectrophotometric methods is a difficult problem in analytical chemistry, due to spectral interferences. By multivariate calibration methods, such as partial least squares (PLS), it is possible to obtain a model adjusted to the concentration values of the mixtures used in the calibration range. Orthogonal signal correction (OSC) is a preprocessing technique used to remove the information unrelated to the target variables based on constrained principal component analysis. OSC is a suitable preprocessing method for partial least squares calibration of mixtures without loss of prediction capacity using spectrophotometric method. In this study, the calibration model is based on absorption spectra in the 450-600 nm range for 21 different mixtures of manganese(II) and iron(II). Calibration matrices were containing 0.05-1.2 and 0.1-2.3 microg mL(-1) Mn(II) and Fe(II), respectively. The RMSEP for manganese(II) and iron(II) with OSC and without OSC were 0.0316, 0.0291, and 0.0907, 0.115, respectively. This procedure allows the simultaneous determination of manganese(II) and iron(II) in synthetic and real matrix samples with good reliability of the determination.

About this research paper

What this paper is about

The simultaneous determination of manganese(II) and iron(II) mixtures by using spectrophotometric methods is a difficult problem in analytical chemistry, due to spectral interferences. By multivariate calibration methods, such as partial least squares (PLS), it is possible to obtain a model adjusted to the concentration values of the mixtures used in the calibration range. Orthogonal signal correction (OSC) is a preprocessing technique used to remove the information unrelated to the target variables based on constrained principal component analysis. OSC is a suitable preprocessing method for partial least squares calibration of mixtures without loss of prediction capacity using spectrophotometric method. In this study, the calibration model is based on absorption spectra in the 450-600 nm range for 21 different mixtures of manganese(II) and iron(II). Calibration matrices were containing 0.05-1.2 and 0.1-2.3 microg mL(-1) Mn(II) and Fe(II), respectively. The RMSEP for manganese(II) and iron(II) with OSC and without OSC were 0.0316, 0.0291, and 0.0907, 0.115, respectively. This procedure allows the simultaneous determination of manganese(II) and iron(II) in synthetic and real matrix samples with good reliability of the determination.

Why it matters

OpenAlex reports 16 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The simultaneous determination of manganese(II) and iron(II) mixtures by using spectrophotometric methods is a difficult problem in analytical chemistry, due to spectral interferences. By multivariate calibration methods, such as partial least squares (PLS), it is possible to obtain a model adjusted to the concentration values of the mixtures used in the calibration range. Orthogonal signal correction (OSC) is a preprocessing technique used to remove the information unrelated to the target variables based on constrained principal component analysis. OSC is a suitable preprocessing method for partial least squares calibration of mixtures without loss of prediction capacity using spectrophotometric method. In this study, the calibration model is based on absorption spectra in the 450-600 nm range for 21 different mixtures of manganese(II) and iron(II). Calibration matrices were containing 0.05-1.2 and 0.1-2.3 microg mL(-1) Mn(II) and Fe(II), respectively. The RMSEP for manganese(II) and iron(II) with OSC and without OSC were 0.0316, 0.0291, and 0.0907, 0.115, respectively. This procedure allows the simultaneous determination of manganese(II) and iron(II) in synthetic and real matrix samples with good reliability of the determination.

Key concepts: Manganese, Partial least squares regression, Calibration, Chemistry, Analytical Chemistry (journal), Matrix (chemical analysis), Chromatography, Mathematics

Related papers

Back to paper searchBrowse research topicsOriginal source
Spectrophotometric Simultaneous Determination of Manganese(II) and Iron(II) in Pharmaceutical by Orthogonal Signal Correction‐Partial Least Squares — Research Paper | ScholarLens