2004Catheterization and Cardiovascular InterventionsRequires access

Contribution of early lumen loss after balloon angioplasty for in‐stent restenosis to lumen loss at follow‐up

Kenichi Fujii, Motomaru Masutani, Yoshio Kobayashi, Jun Tateishi, Daizo Kawasaki, Mitsumasa Ohyanagi, Gary S. Mintz, Martin B. Leon

Open publisher page 2 citations

Abstract

The treatment of in-stent restenosis using balloon angioplasty alone often produces excellent early results, but is associated with high rate of recurrence. Previous studies have demonstrated significant tissue reintrusion shortly after the treatment of in-stent restenosis with balloon angioplasty. The study was designed to elucidate the contribution of early lumen loss 6 hr after balloon angioplasty to lumen loss at follow-up. We prospectively performed quantitative coronary angiography and intravascular ultrasound in 12 patients with in-stent restenosis before intervention, after the final procedure, 6 hr later (5.6 +/- 1.4 hr), and at follow-up (7.7 +/- 2.3 months). Compared with immediately after balloon angioplasty, by 6 hr postintervention, the minimum lumen diameter (MLD) and lumen cross-sectional area had decreased significantly (2.48 +/- 0.44 to 2.01 +/- 0.57 mm, P = 0.01, and 7.0 +/- 1.2 to 5.5 +/- 1.4 mm2, P = 0.004, respectively). Furthermore, the MLD decreased further between 6 hr postintervention and long-term follow-up (2.01 +/- 0.57 to 1.55 +/- 0.64 mm; P = 0.001). Patients who showed recurrence of restenosis at follow-up had greater early lumen loss than patients without recurrence of restenosis (0.71 +/- 0.31 vs. 0.23 +/- 0.13 mm; P = 0.006). Diffuse lesions had greater early lumen loss compared to focal lesions (0.75 +/- 0.35 vs. 0.28 +/- 0.13 mm; P = 0.008). Early lumen loss is common after the treatment of in-stent restenosis by balloon angioplasty. Within the first 6 hr postintervention, 32% +/- 29% of acute lumen gain is lost, and early lumen loss contributed to 42% +/- 18% of total lumen loss at follow-up.

About this research paper

What this paper is about

The treatment of in-stent restenosis using balloon angioplasty alone often produces excellent early results, but is associated with high rate of recurrence. Previous studies have demonstrated significant tissue reintrusion shortly after the treatment of in-stent restenosis with balloon angioplasty. The study was designed to elucidate the contribution of early lumen loss 6 hr after balloon angioplasty to lumen loss at follow-up. We prospectively performed quantitative coronary angiography and intravascular ultrasound in 12 patients with in-stent restenosis before intervention, after the final procedure, 6 hr later (5.6 +/- 1.4 hr), and at follow-up (7.7 +/- 2.3 months). Compared with immediately after balloon angioplasty, by 6 hr postintervention, the minimum lumen diameter (MLD) and lumen cross-sectional area had decreased significantly (2.48 +/- 0.44 to 2.01 +/- 0.57 mm, P = 0.01, and 7.0 +/- 1.2 to 5.5 +/- 1.4 mm2, P = 0.004, respectively). Furthermore, the MLD decreased further between 6 hr postintervention and long-term follow-up (2.01 +/- 0.57 to 1.55 +/- 0.64 mm; P = 0.001). Patients who showed recurrence of restenosis at follow-up had greater early lumen loss than patients without recurrence of restenosis (0.71 +/- 0.31 vs. 0.23 +/- 0.13 mm; P = 0.006). Diffuse lesions had greater early lumen loss compared to focal lesions (0.75 +/- 0.35 vs. 0.28 +/- 0.13 mm; P = 0.008). Early lumen loss is common after the treatment of in-stent restenosis by balloon angioplasty. Within the first 6 hr postintervention, 32% +/- 29% of acute lumen gain is lost, and early lumen loss contributed to 42% +/- 18% of total lumen loss at follow-up.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The treatment of in-stent restenosis using balloon angioplasty alone often produces excellent early results, but is associated with high rate of recurrence. Previous studies have demonstrated significant tissue reintrusion shortly after the treatment of in-stent restenosis with balloon angioplasty. The study was designed to elucidate the contribution of early lumen loss 6 hr after balloon angioplasty to lumen loss at follow-up. We prospectively performed quantitative coronary angiography and intravascular ultrasound in 12 patients with in-stent restenosis before intervention, after the final procedure, 6 hr later (5.6 +/- 1.4 hr), and at follow-up (7.7 +/- 2.3 months). Compared with immediately after balloon angioplasty, by 6 hr postintervention, the minimum lumen diameter (MLD) and lumen cross-sectional area had decreased significantly (2.48 +/- 0.44 to 2.01 +/- 0.57 mm, P = 0.01, and 7.0 +/- 1.2 to 5.5 +/- 1.4 mm2, P = 0.004, respectively). Furthermore, the MLD decreased further between 6 hr postintervention and long-term follow-up (2.01 +/- 0.57 to 1.55 +/- 0.64 mm; P = 0.001). Patients who showed recurrence of restenosis at follow-up had greater early lumen loss than patients without recurrence of restenosis (0.71 +/- 0.31 vs. 0.23 +/- 0.13 mm; P = 0.006). Diffuse lesions had greater early lumen loss compared to focal lesions (0.75 +/- 0.35 vs. 0.28 +/- 0.13 mm; P = 0.008). Early lumen loss is common after the treatment of in-stent restenosis by balloon angioplasty. Within the first 6 hr postintervention, 32% +/- 29% of acute lumen gain is lost, and early lumen loss contributed to 42% +/- 18% of total lumen loss at follow-up.

Key concepts: Medicine, Balloon, Lumen (anatomy), Restenosis, Angioplasty, Coronary restenosis, Stent, Radiology

Related papers

Back to paper searchBrowse research topicsOriginal source
Contribution of early lumen loss after balloon angioplasty for in‐stent restenosis to lumen loss at follow‐up — Research Paper | ScholarLens