2007•Analytical LettersRequires access

Multicomponent Titration of Calcium + Magnesium Mixtures Employing a Potentiometric Electronic‐Tongue

Daniel Calvo, Jordi Bartrolı́, Manel del Valle

Open publisher page 5 citations

Abstract

A fast novel potentiometric titration procedure is proposed, in which the detection system is formed by a potentiometric electronic tongue. The titration consists in a reduced number of fixed titrant additions to the sample and the recording of the potentials of an array of Ion Selective Electrodes. The obtained data matrix is entered to an Artificial Neural Network response model, previously trained to furnish concentrations of a multicomponent mixture. The principle is demonstrated with automated EDTA titration of mixtures of Ca2+ and Mg2+ at fixed pH 8.5. In this case, five 2 ml fixed volume additions plus the readings of four sensors were adequate for the resolution of the mixture. In the conditions used, titration was feasible up to 3.3 mM total ion concentration, the precision was estimated as 3.20% RSD for Ca2+ and 2.76% RSD for Mg2+ (n=5), and the detection limits 0.16 mM Ca2+ and 0.26 mM Mg2+. The procedure was applied to mineral waters and compared with reference methods (correlation=0.92 for Ca2+ and correlation=0.89 for Mg2+, n=14).

About this research paper

What this paper is about

A fast novel potentiometric titration procedure is proposed, in which the detection system is formed by a potentiometric electronic tongue. The titration consists in a reduced number of fixed titrant additions to the sample and the recording of the potentials of an array of Ion Selective Electrodes. The obtained data matrix is entered to an Artificial Neural Network response model, previously trained to furnish concentrations of a multicomponent mixture. The principle is demonstrated with automated EDTA titration of mixtures of Ca2+ and Mg2+ at fixed pH 8.5. In this case, five 2 ml fixed volume additions plus the readings of four sensors were adequate for the resolution of the mixture. In the conditions used, titration was feasible up to 3.3 mM total ion concentration, the precision was estimated as 3.20% RSD for Ca2+ and 2.76% RSD for Mg2+ (n=5), and the detection limits 0.16 mM Ca2+ and 0.26 mM Mg2+. The procedure was applied to mineral waters and compared with reference methods (correlation=0.92 for Ca2+ and correlation=0.89 for Mg2+, n=14).

Why it matters

OpenAlex reports 5 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A fast novel potentiometric titration procedure is proposed, in which the detection system is formed by a potentiometric electronic tongue. The titration consists in a reduced number of fixed titrant additions to the sample and the recording of the potentials of an array of Ion Selective Electrodes. The obtained data matrix is entered to an Artificial Neural Network response model, previously trained to furnish concentrations of a multicomponent mixture. The principle is demonstrated with automated EDTA titration of mixtures of Ca2+ and Mg2+ at fixed pH 8.5. In this case, five 2 ml fixed volume additions plus the readings of four sensors were adequate for the resolution of the mixture. In the conditions used, titration was feasible up to 3.3 mM total ion concentration, the precision was estimated as 3.20% RSD for Ca2+ and 2.76% RSD for Mg2+ (n=5), and the detection limits 0.16 mM Ca2+ and 0.26 mM Mg2+. The procedure was applied to mineral waters and compared with reference methods (correlation=0.92 for Ca2+ and correlation=0.89 for Mg2+, n=14).

Key concepts: Electronic tongue, Potentiometric titration, Chemistry, Titration, Complexometric titration, Analytical Chemistry (journal), Magnesium, Amperometric titration

Related papers

Back to paper searchBrowse research topicsOriginal source
Multicomponent Titration of Calcium + Magnesium Mixtures Employing a Potentiometric Electronic‐Tongue — Research Paper | ScholarLens