2013SpringerPlusOpen access

New pulse wave measurement method using different hold-down wrist pressures according to individual patient characteristics

Seong Ki Yoo, Ki-Young Shin, Tae Bum Lee, Seung Oh Jin

Open full text 16 citations

Abstract

In traditional Chinese and Korean medicine, doctors first observe a patient's pulse by gently and strongly pressing their fingers onto the wrist, and then make a diagnosis based on the observed pulse waves. The most common method to implement this diagnostic technique is to mechanically extract the pulse waves by applying a fixed range of pressures for all patients. However, this method does not consider the patients individual characteristics such as age, sex, and skin thickness. In the present study, we propose a new method of pulse wave extraction that incorporates the personal characteristics of the patients. This method measures the pulse wave signal at varying hold-down pressures, rather than applying a fixed hold-down pressure for all patients. To compare this new technique with existing methods, we extracted pulse waves from 20 subjects, and then determined the actual applied pressure at each step, the coefficient of floating and sinking pulse (CFS), and the distinction of floating/sinking pulse for each group. Consequently, each subject had a different pressure range in our proposed method, whereas all subjects had a similar pressure range in the existing method. Four of 20 subjects exhibited different floating/sinking pulse patterns due to the value of the first pressure step and the range of hold-down pressures. These four subjects were categorized as overweight based on BMI. In addition, the moving distance of the proposed method was longer than the existing method (p = 0.003, paired t-test), and the correlation coefficient between CFS values of two different methods was 0.321, indicating that there was no correlation.

Open-access reader

About this research paper

What this paper is about

In traditional Chinese and Korean medicine, doctors first observe a patient's pulse by gently and strongly pressing their fingers onto the wrist, and then make a diagnosis based on the observed pulse waves. The most common method to implement this diagnostic technique is to mechanically extract the pulse waves by applying a fixed range of pressures for all patients. However, this method does not consider the patients individual characteristics such as age, sex, and skin thickness. In the present study, we propose a new method of pulse wave extraction that incorporates the personal characteristics of the patients. This method measures the pulse wave signal at varying hold-down pressures, rather than applying a fixed hold-down pressure for all patients. To compare this new technique with existing methods, we extracted pulse waves from 20 subjects, and then determined the actual applied pressure at each step, the coefficient of floating and sinking pulse (CFS), and the distinction of floating/sinking pulse for each group. Consequently, each subject had a different pressure range in our proposed method, whereas all subjects had a similar pressure range in the existing method. Four of 20 subjects exhibited different floating/sinking pulse patterns due to the value of the first pressure step and the range of hold-down pressures. These four subjects were categorized as overweight based on BMI. In addition, the moving distance of the proposed method was longer than the existing method (p = 0.003, paired t-test), and the correlation coefficient between CFS values of two different methods was 0.321, indicating that there was no correlation.

Why it matters

OpenAlex reports 16 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In traditional Chinese and Korean medicine, doctors first observe a patient's pulse by gently and strongly pressing their fingers onto the wrist, and then make a diagnosis based on the observed pulse waves. The most common method to implement this diagnostic technique is to mechanically extract the pulse waves by applying a fixed range of pressures for all patients. However, this method does not consider the patients individual characteristics such as age, sex, and skin thickness. In the present study, we propose a new method of pulse wave extraction that incorporates the personal characteristics of the patients. This method measures the pulse wave signal at varying hold-down pressures, rather than applying a fixed hold-down pressure for all patients. To compare this new technique with existing methods, we extracted pulse waves from 20 subjects, and then determined the actual applied pressure at each step, the coefficient of floating and sinking pulse (CFS), and the distinction of floating/sinking pulse for each group. Consequently, each subject had a different pressure range in our proposed method, whereas all subjects had a similar pressure range in the existing method. Four of 20 subjects exhibited different floating/sinking pulse patterns due to the value of the first pressure step and the range of hold-down pressures. These four subjects were categorized as overweight based on BMI. In addition, the moving distance of the proposed method was longer than the existing method (p = 0.003, paired t-test), and the correlation coefficient between CFS values of two different methods was 0.321, indicating that there was no correlation.

Key concepts: Pulse (music), Pulse wave, Range (aeronautics), Acoustics, SIGNAL (programming language), Pulse Wave Analysis, Wrist, Biomedical engineering

Related papers

Back to paper searchBrowse research topicsOriginal source
New pulse wave measurement method using different hold-down wrist pressures according to individual patient characteristics — Research Paper | ScholarLens