2009The FASEB JournalRequires access

Can Augmentation Index Quantify Impact of Pulse Wave Reflection in Isolated Systolic Hypertension?

Mohammad Waqar Mohiuddin, Christopher M. Quick

Open publisher page 0 citations

Abstract

Systolic and diastolic blood pressures are determined, in part, by pressure pulse‐waves generated by the heart that are reflected back from multiple sites in the periphery. The magnitude and timing of the reflected pulse‐wave is significantly altered in isolated systolic hypertension (ISH), and results in significant changes in pulse pressure morphology. Conventional belief states that the recorded aortic pressure above a distinctive inflection point in the systolic pulse contour is a result of 'augmentation' due to the early arrival of reflected pulse‐wave. Accordingly, the ratio of augmented pressure to pulse pressure, Augmentation Index (AI), has been introduced to quantify the contribution of reflection. To test AI estimation, we utilized a 121‐element arterial system model which predicts realistic pressure and flow in the vessel segments, followed by analysis of experimental data, to demonstrate that the notion of augmentation index widely misinterprets the contribution of reflected waves in cases of a very compliant system or ISH. In the first case, forward and reflected pulses can add destructively and thus decrease pulse pressure, rather than augment it, resulting in negative augmentation. In the second case, the arterial system degenerates into a classical 2‐element Windkessel, and pulse wave reflection ceases to affect arterial pressure pulses, resulting in 37% overestimation of augmentation.

About this research paper

What this paper is about

Systolic and diastolic blood pressures are determined, in part, by pressure pulse‐waves generated by the heart that are reflected back from multiple sites in the periphery. The magnitude and timing of the reflected pulse‐wave is significantly altered in isolated systolic hypertension (ISH), and results in significant changes in pulse pressure morphology. Conventional belief states that the recorded aortic pressure above a distinctive inflection point in the systolic pulse contour is a result of 'augmentation' due to the early arrival of reflected pulse‐wave. Accordingly, the ratio of augmented pressure to pulse pressure, Augmentation Index (AI), has been introduced to quantify the contribution of reflection. To test AI estimation, we utilized a 121‐element arterial system model which predicts realistic pressure and flow in the vessel segments, followed by analysis of experimental data, to demonstrate that the notion of augmentation index widely misinterprets the contribution of reflected waves in cases of a very compliant system or ISH. In the first case, forward and reflected pulses can add destructively and thus decrease pulse pressure, rather than augment it, resulting in negative augmentation. In the second case, the arterial system degenerates into a classical 2‐element Windkessel, and pulse wave reflection ceases to affect arterial pressure pulses, resulting in 37% overestimation of augmentation.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Systolic and diastolic blood pressures are determined, in part, by pressure pulse‐waves generated by the heart that are reflected back from multiple sites in the periphery. The magnitude and timing of the reflected pulse‐wave is significantly altered in isolated systolic hypertension (ISH), and results in significant changes in pulse pressure morphology. Conventional belief states that the recorded aortic pressure above a distinctive inflection point in the systolic pulse contour is a result of 'augmentation' due to the early arrival of reflected pulse‐wave. Accordingly, the ratio of augmented pressure to pulse pressure, Augmentation Index (AI), has been introduced to quantify the contribution of reflection. To test AI estimation, we utilized a 121‐element arterial system model which predicts realistic pressure and flow in the vessel segments, followed by analysis of experimental data, to demonstrate that the notion of augmentation index widely misinterprets the contribution of reflected waves in cases of a very compliant system or ISH. In the first case, forward and reflected pulses can add destructively and thus decrease pulse pressure, rather than augment it, resulting in negative augmentation. In the second case, the arterial system degenerates into a classical 2‐element Windkessel, and pulse wave reflection ceases to affect arterial pressure pulses, resulting in 37% overestimation of augmentation.

Key concepts: Pulse (music), Pulse pressure, Pulse Wave Analysis, Blood pressure, Inflection point, Pulse wave, Reflection (computer programming), Cardiology

Related papers

Back to paper searchBrowse research topicsOriginal source
Can Augmentation Index Quantify Impact of Pulse Wave Reflection in Isolated Systolic Hypertension? — Research Paper | ScholarLens