Echo‐doppler measurement of splanchnic blood flow in control and cirrhotic subjects
Marco Zoli, Giulio Marchesini, Maria Rita Cordiani, P Pisi, Alessandra Brunori, Antonio Trono, E Pisi
Abstract
Marco Zoli, Giulio Marchesini, Maria Rita Cordiani, P Pisi, Alessandra Brunori, Antonio Trono, E Pisi
Abstract
Blood flow in the splanchnic veins was studied in cirrhotics and matched controls by means of a system that combines a mechanical sector scanner with a pulsed Doppler. The measurements were validated in an in vitro model. Echo-doppler studies could be carried out reproducibly in only approximately two-thirds of cases because of poor echo transmission or incomplete cooperation. Portal blood velocity was significantly reduced in cirrhotics (10.5 +/- 0.6 cm/s versus 16.0 +/- 0.5 in controls; p less than 0.001), but portal blood flow was normal because of enlarged portal caliber. A complete hemodynamic evaluation of the splenic and superior mesenteric veins was possible in only a few subjects. In selected patients the technique may prove relevant in the study of hemodynamic effects of drugs and surgery on portal blood flow.
OpenAlex reports 116 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Blood flow in the splanchnic veins was studied in cirrhotics and matched controls by means of a system that combines a mechanical sector scanner with a pulsed Doppler. The measurements were validated in an in vitro model. Echo-doppler studies could be carried out reproducibly in only approximately two-thirds of cases because of poor echo transmission or incomplete cooperation. Portal blood velocity was significantly reduced in cirrhotics (10.5 +/- 0.6 cm/s versus 16.0 +/- 0.5 in controls; p less than 0.001), but portal blood flow was normal because of enlarged portal caliber. A complete hemodynamic evaluation of the splenic and superior mesenteric veins was possible in only a few subjects. In selected patients the technique may prove relevant in the study of hemodynamic effects of drugs and surgery on portal blood flow.
Key concepts: Medicine, Splanchnic, Hemodynamics, Blood flow, Splanchnic Circulation, Doppler effect, Portal hypertension, Echo (communications protocol)