2003American Journal of Clinical PathologyRequires access

Evaluation of Urine Specimen Integrity in a Public Health STD Screening Program

Nathan C. Birch, Douglas F. Stickle, Anita Young, Philip Medina, Steven H. Hinrichs

Open publisher page 3 citations

Abstract

Detection of Chlamydia trachomatis and/or Neisseria gonorrhoeae infection in urine using molecular amplification assays has permitted institutions with limited medical facilities to offer testing for these sexually transmitted diseases (STDs). The Nebraska Public Health Laboratory (NPHL) investigated the validity of urine samples submitted for C trachomatis and/or N gonorrhoeae amplification after receiving a substantial number of clear specimens. Approximately 75% of all urine specimens submitted for STD testing to the NPHL were from correctional facilities. The falsification of urine specimens submitted for microbiology studies is not evaluated routinely, and this problem was previously undocumented. By using the criteria for specific gravity of 1.001 or less and a creatinine concentration of less than 5 mg/dL (442 mumol/L), approximately 8% of all specimens submitted during the study interval were determined to be inconsistent with urine. The microbiology laboratory should be aware of the possibility for specimen manipulation to identify facilities submitting falsified specimens, to initiate appropriate intervention, and to minimize false-negative reporting.

About this research paper

What this paper is about

Detection of Chlamydia trachomatis and/or Neisseria gonorrhoeae infection in urine using molecular amplification assays has permitted institutions with limited medical facilities to offer testing for these sexually transmitted diseases (STDs). The Nebraska Public Health Laboratory (NPHL) investigated the validity of urine samples submitted for C trachomatis and/or N gonorrhoeae amplification after receiving a substantial number of clear specimens. Approximately 75% of all urine specimens submitted for STD testing to the NPHL were from correctional facilities. The falsification of urine specimens submitted for microbiology studies is not evaluated routinely, and this problem was previously undocumented. By using the criteria for specific gravity of 1.001 or less and a creatinine concentration of less than 5 mg/dL (442 mumol/L), approximately 8% of all specimens submitted during the study interval were determined to be inconsistent with urine. The microbiology laboratory should be aware of the possibility for specimen manipulation to identify facilities submitting falsified specimens, to initiate appropriate intervention, and to minimize false-negative reporting.

Why it matters

OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Detection of Chlamydia trachomatis and/or Neisseria gonorrhoeae infection in urine using molecular amplification assays has permitted institutions with limited medical facilities to offer testing for these sexually transmitted diseases (STDs). The Nebraska Public Health Laboratory (NPHL) investigated the validity of urine samples submitted for C trachomatis and/or N gonorrhoeae amplification after receiving a substantial number of clear specimens. Approximately 75% of all urine specimens submitted for STD testing to the NPHL were from correctional facilities. The falsification of urine specimens submitted for microbiology studies is not evaluated routinely, and this problem was previously undocumented. By using the criteria for specific gravity of 1.001 or less and a creatinine concentration of less than 5 mg/dL (442 mumol/L), approximately 8% of all specimens submitted during the study interval were determined to be inconsistent with urine. The microbiology laboratory should be aware of the possibility for specimen manipulation to identify facilities submitting falsified specimens, to initiate appropriate intervention, and to minimize false-negative reporting.

Key concepts: Chlamydia trachomatis, Urine, Neisseria gonorrhoeae, Medicine, Gonorrhea, Urine sample, Sexually transmitted disease, Chlamydia

Related papers

Back to paper searchBrowse research topicsOriginal source
Evaluation of Urine Specimen Integrity in a Public Health STD Screening Program — Research Paper | ScholarLens