2006Unpublished venueRequires access

Integration of Single Ion Implantation Method in Focused Ion Beam System for Nanofabrication

Changyi Yang, David N. Jamieson, Sean Hearne, Toby Hopf, Chris I. Pakes, Steven Prawer, Søren E. S. Andresen, Andrew S. Dzurak, E. Gauja, Fay E. Hudson, Robert Graham Clark

Open publisher page 3 citations

Abstract

A method of single ion implantation based on the online detection of individual ion impacts on a pure silicon substrate has been implemented in a focused ion beam (FIB) system. The optimized silicon detector integrated with a state-of-art low noise electronic system and operated at a low temperature makes it possible to achieve single ion detection with a minimum energy detection limit about 1 to 3.5 keV in a FIB chamber. The method of single ion implantation is compatible with a nanofabrication process. The lateral positioning of the implantation sites are controlled to nanometer accuracy (~5 nm) using nanofabricated PMMA masks. The implantation depth is controlled by tuning the single ion energy to a certain energy level (5-30 keV). The system has been successfully tested in the detection of 30 keV Si+ single ions. The counting of single ion implantation in each site is achieved by the detection of e-h pairs (an outcome of ionization energy) produced by the ion-solid interaction; each 30 keV Si+ ion implanting through a 5 nm SiO2surface layer and stopping at a pure silicon substrate produces an average ionization energy about 7.0 keV. A further development for improving a detection limit down to less than 1 keV in FIB for low energy phosphorus implantation and detection is outlined. Fabrication of nanometer-scaled phosphorus arrays for the application of qubits construction is discussed.

About this research paper

What this paper is about

A method of single ion implantation based on the online detection of individual ion impacts on a pure silicon substrate has been implemented in a focused ion beam (FIB) system. The optimized silicon detector integrated with a state-of-art low noise electronic system and operated at a low temperature makes it possible to achieve single ion detection with a minimum energy detection limit about 1 to 3.5 keV in a FIB chamber. The method of single ion implantation is compatible with a nanofabrication process. The lateral positioning of the implantation sites are controlled to nanometer accuracy (~5 nm) using nanofabricated PMMA masks. The implantation depth is controlled by tuning the single ion energy to a certain energy level (5-30 keV). The system has been successfully tested in the detection of 30 keV Si+ single ions. The counting of single ion implantation in each site is achieved by the detection of e-h pairs (an outcome of ionization energy) produced by the ion-solid interaction; each 30 keV Si+ ion implanting through a 5 nm SiO2surface layer and stopping at a pure silicon substrate produces an average ionization energy about 7.0 keV. A further development for improving a detection limit down to less than 1 keV in FIB for low energy phosphorus implantation and detection is outlined. Fabrication of nanometer-scaled phosphorus arrays for the application of qubits construction is discussed.

Why it matters

OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A method of single ion implantation based on the online detection of individual ion impacts on a pure silicon substrate has been implemented in a focused ion beam (FIB) system. The optimized silicon detector integrated with a state-of-art low noise electronic system and operated at a low temperature makes it possible to achieve single ion detection with a minimum energy detection limit about 1 to 3.5 keV in a FIB chamber. The method of single ion implantation is compatible with a nanofabrication process. The lateral positioning of the implantation sites are controlled to nanometer accuracy (~5 nm) using nanofabricated PMMA masks. The implantation depth is controlled by tuning the single ion energy to a certain energy level (5-30 keV). The system has been successfully tested in the detection of 30 keV Si+ single ions. The counting of single ion implantation in each site is achieved by the detection of e-h pairs (an outcome of ionization energy) produced by the ion-solid interaction; each 30 keV Si+ ion implanting through a 5 nm SiO2surface layer and stopping at a pure silicon substrate produces an average ionization energy about 7.0 keV. A further development for improving a detection limit down to less than 1 keV in FIB for low energy phosphorus implantation and detection is outlined. Fabrication of nanometer-scaled phosphorus arrays for the application of qubits construction is discussed.

Key concepts: Ion implantation, Materials science, Silicon, Ion beam, Ion, Focused ion beam, Nanolithography, Ion beam deposition

Related papers

Back to paper searchBrowse research topicsOriginal source
Integration of Single Ion Implantation Method in Focused Ion Beam System for Nanofabrication — Research Paper | ScholarLens