Multiparameter Respiratory Rate Estimation From the Photoplethysmogram
Walter Karlen, S. Raman, J. Mark Ansermino, Guy Albert Dumont
Abstract
Walter Karlen, S. Raman, J. Mark Ansermino, Guy Albert Dumont
Abstract
We present a novel method for estimating respiratory rate in real time from the photoplethysmogram (PPG) obtained from pulse oximetry. Three respiratory-induced variations (frequency, intensity, and amplitude) are extracted from the PPG using the Incremental-Merge Segmentation algorithm. Frequency content of each respiratory-induced variation is analyzed using fast Fourier transforms. The proposed Smart Fusion method then combines the results of the three respiratory-induced variations using a transparent mean calculation. It automatically eliminates estimations considered to be unreliable because of detected presence of artifacts in the PPG or disagreement between the different individual respiratory rate estimations. The algorithm has been tested on data obtained from 29 children and 13 adults. Results show that it is important to combine the three respiratory-induced variations for robust estimation of respiratory rate. The Smart Fusion showed trends of improved estimation (mean root mean square error 3.0 breaths/min) compared to the individual estimation methods (5.8, 6.2, and 3.9 breaths/min). The Smart Fusion algorithm is being implemented in a mobile phone pulse oximeter device to facilitate the diagnosis of severe childhood pneumonia in remote areas.
OpenAlex reports 496 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
We present a novel method for estimating respiratory rate in real time from the photoplethysmogram (PPG) obtained from pulse oximetry. Three respiratory-induced variations (frequency, intensity, and amplitude) are extracted from the PPG using the Incremental-Merge Segmentation algorithm. Frequency content of each respiratory-induced variation is analyzed using fast Fourier transforms. The proposed Smart Fusion method then combines the results of the three respiratory-induced variations using a transparent mean calculation. It automatically eliminates estimations considered to be unreliable because of detected presence of artifacts in the PPG or disagreement between the different individual respiratory rate estimations. The algorithm has been tested on data obtained from 29 children and 13 adults. Results show that it is important to combine the three respiratory-induced variations for robust estimation of respiratory rate. The Smart Fusion showed trends of improved estimation (mean root mean square error 3.0 breaths/min) compared to the individual estimation methods (5.8, 6.2, and 3.9 breaths/min). The Smart Fusion algorithm is being implemented in a mobile phone pulse oximeter device to facilitate the diagnosis of severe childhood pneumonia in remote areas.
Key concepts: Photoplethysmogram, Respiratory rate, Pulse oximetry, Computer science, Mean squared error, Respiratory system, Pattern recognition (psychology), Speech recognition