1994•IEEE Transactions on Nuclear ScienceRequires access

Study on the use of transmission scans for whole body PET attenuation correction

Arion F. Chatziioannou, Magnus L Dahlbom, Carl K. Hoh

Open publisher page 15 citations

Abstract

Transmission scans for attenuation correction of whole body PET studies are not acquired routinely, since noise considerations impose acquisition time constraints that make conventional scanning techniques infeasible. The aim of this work is to optimize data acquisition and processing parameters and improve the SNR of whole body transmission scans, in order to achieve within a reasonable time frame, an attenuation correction of the same quality as in cardiac PET. Methods to improve the scanner sensitivity by using additional coincidence planes, as well as smoothing methods for the randoms and the transmission data were investigated. Phantom and patient studies show that transmission scans are feasible for whole body PET studies, with equivalent noise introduced in the chest area as in a typical cardiac PET attenuation correction, at fractions of the time required by conventional transmission scan protocols.>

About this research paper

What this paper is about

Transmission scans for attenuation correction of whole body PET studies are not acquired routinely, since noise considerations impose acquisition time constraints that make conventional scanning techniques infeasible. The aim of this work is to optimize data acquisition and processing parameters and improve the SNR of whole body transmission scans, in order to achieve within a reasonable time frame, an attenuation correction of the same quality as in cardiac PET. Methods to improve the scanner sensitivity by using additional coincidence planes, as well as smoothing methods for the randoms and the transmission data were investigated. Phantom and patient studies show that transmission scans are feasible for whole body PET studies, with equivalent noise introduced in the chest area as in a typical cardiac PET attenuation correction, at fractions of the time required by conventional transmission scan protocols.>

Why it matters

OpenAlex reports 15 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Transmission scans for attenuation correction of whole body PET studies are not acquired routinely, since noise considerations impose acquisition time constraints that make conventional scanning techniques infeasible. The aim of this work is to optimize data acquisition and processing parameters and improve the SNR of whole body transmission scans, in order to achieve within a reasonable time frame, an attenuation correction of the same quality as in cardiac PET. Methods to improve the scanner sensitivity by using additional coincidence planes, as well as smoothing methods for the randoms and the transmission data were investigated. Phantom and patient studies show that transmission scans are feasible for whole body PET studies, with equivalent noise introduced in the chest area as in a typical cardiac PET attenuation correction, at fractions of the time required by conventional transmission scan protocols.>

Key concepts: Correction for attenuation, Attenuation, Scanner, Imaging phantom, Cardiac PET, Transmission (telecommunications), Noise (video), Computer science

Related papers

Back to paper searchBrowse research topicsOriginal source
Study on the use of transmission scans for whole body PET attenuation correction — Research Paper | ScholarLens