2005•IEEE Transactions on Nuclear ScienceRequires access

Attenuation correction for the NIH ATLAS small animal PET scanner

Rutao Yao, Jürgen Seidel, Jeih‐San Liow, M.V. Green

Open publisher page 16 citations

Abstract

We evaluated an analytic attenuation correction method for the National Institutes of Health (NIH) Advanced Technology Laboratory Animal Scanner (ATLAS) small animal positron emission tomography (PET) scanner. This method is based on the body outline of emission images and an average empirical /spl mu/ (linear attenuation coefficient) value. We evaluated this method using a computed tomography (CT)-based attenuation correction (ACs) as the "gold standard." A specially fabricated attenuation calibration phantom with cylindrical inserts that mimic different body tissues was used to derive the relationship to convert CT values to /spl mu/ for PET. The methods were applied to three test data sets: 1) a uniform cylinder phantom, 2) the attenuation calibration phantom, and 3) a mouse injected with [/sup 18/F]FDG. CT-based correction achieved activity restorations expected for all three data sets. The analytic method showed similar correction factors for the cylinder phantom and the mouse for which the attenuation medium volume matches the detectable emission source distribution. The correction factor for the attenuation calibration phantom was smaller because the emission image outline underestimated the attenuation medium volume.

About this research paper

What this paper is about

We evaluated an analytic attenuation correction method for the National Institutes of Health (NIH) Advanced Technology Laboratory Animal Scanner (ATLAS) small animal positron emission tomography (PET) scanner. This method is based on the body outline of emission images and an average empirical /spl mu/ (linear attenuation coefficient) value. We evaluated this method using a computed tomography (CT)-based attenuation correction (ACs) as the "gold standard." A specially fabricated attenuation calibration phantom with cylindrical inserts that mimic different body tissues was used to derive the relationship to convert CT values to /spl mu/ for PET. The methods were applied to three test data sets: 1) a uniform cylinder phantom, 2) the attenuation calibration phantom, and 3) a mouse injected with [/sup 18/F]FDG. CT-based correction achieved activity restorations expected for all three data sets. The analytic method showed similar correction factors for the cylinder phantom and the mouse for which the attenuation medium volume matches the detectable emission source distribution. The correction factor for the attenuation calibration phantom was smaller because the emission image outline underestimated the attenuation medium volume.

Why it matters

OpenAlex reports 16 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

We evaluated an analytic attenuation correction method for the National Institutes of Health (NIH) Advanced Technology Laboratory Animal Scanner (ATLAS) small animal positron emission tomography (PET) scanner. This method is based on the body outline of emission images and an average empirical /spl mu/ (linear attenuation coefficient) value. We evaluated this method using a computed tomography (CT)-based attenuation correction (ACs) as the "gold standard." A specially fabricated attenuation calibration phantom with cylindrical inserts that mimic different body tissues was used to derive the relationship to convert CT values to /spl mu/ for PET. The methods were applied to three test data sets: 1) a uniform cylinder phantom, 2) the attenuation calibration phantom, and 3) a mouse injected with [/sup 18/F]FDG. CT-based correction achieved activity restorations expected for all three data sets. The analytic method showed similar correction factors for the cylinder phantom and the mouse for which the attenuation medium volume matches the detectable emission source distribution. The correction factor for the attenuation calibration phantom was smaller because the emission image outline underestimated the attenuation medium volume.

Key concepts: Imaging phantom, Correction for attenuation, Attenuation, Scanner, Calibration, Attenuation coefficient, Positron emission tomography, Nuclear medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
Attenuation correction for the NIH ATLAS small animal PET scanner — Research Paper | ScholarLens