2007The International Journal of Biological MarkersOpen access

Development of ELISAs for Quantification of HMFG1-Specific Human Anti-Mouse IgG and IgM Antibodies

Angèle L.M. Oei, Otto C. Boerman, Anneke J Geurts-Moespot, J. E. van Eerd, D. van Tienoven, N.S Courtenay-Luck, Chris M.G. Thomas, LF.A.G. Massuger, Fred C.G.J. Sweep

Open full text 2 citations

Abstract

The aim of this study was to develop and validate ELISAs for quantification of HAMA-IgM and HAMA-IgG in serum of patients with ovarian cancer who enrolled in a large international randomized phase III trial of intraperitoneal Yttrium-90-labeled HMFG1 murine monoclonal antibody therapy. The capture antibody of these 2 assays was the murine antibody HMFG1, while mouse anti-human IgM-HRP or mouse anti-human IgG(Fc)-HRP served as tracer antibodies. A pool of HAMA-positive serum samples was used to prepare a series of assay standards and another pool served as reference preparation. The analytical sensitivity of the HAMA-IgM assay was 2.5 arbitrary units per mL (AU/mL) and 4.7 AU/mL for the HAMA-IgG ELISA. Diluted serum samples showed good parallelism with the HAMA-IgM and HAMA-IgG standard dose-response curves. Within-assay coefficient of variation was 7.5% for HAMA-IgM and 6.5% for HAMA-IgG. Between-assay variation was 14.2% for HAMA-IgM and 15.3% for HAMA-IgG. The developed HAMA-IgM and HAMA-IgG ELISAs show satisfactory reliability criteria (sensitivity, parallelism and precision) and are suitable for monitoring of HAMA-IgM and HAMA-IgG responses in ovarian cancer patients. These ELISAs will be used to monitor the development of HAMAs in patients who received radioimmunotherapy with murine HMFG1.

About this research paper

What this paper is about

The aim of this study was to develop and validate ELISAs for quantification of HAMA-IgM and HAMA-IgG in serum of patients with ovarian cancer who enrolled in a large international randomized phase III trial of intraperitoneal Yttrium-90-labeled HMFG1 murine monoclonal antibody therapy. The capture antibody of these 2 assays was the murine antibody HMFG1, while mouse anti-human IgM-HRP or mouse anti-human IgG(Fc)-HRP served as tracer antibodies. A pool of HAMA-positive serum samples was used to prepare a series of assay standards and another pool served as reference preparation. The analytical sensitivity of the HAMA-IgM assay was 2.5 arbitrary units per mL (AU/mL) and 4.7 AU/mL for the HAMA-IgG ELISA. Diluted serum samples showed good parallelism with the HAMA-IgM and HAMA-IgG standard dose-response curves. Within-assay coefficient of variation was 7.5% for HAMA-IgM and 6.5% for HAMA-IgG. Between-assay variation was 14.2% for HAMA-IgM and 15.3% for HAMA-IgG. The developed HAMA-IgM and HAMA-IgG ELISAs show satisfactory reliability criteria (sensitivity, parallelism and precision) and are suitable for monitoring of HAMA-IgM and HAMA-IgG responses in ovarian cancer patients. These ELISAs will be used to monitor the development of HAMAs in patients who received radioimmunotherapy with murine HMFG1.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The aim of this study was to develop and validate ELISAs for quantification of HAMA-IgM and HAMA-IgG in serum of patients with ovarian cancer who enrolled in a large international randomized phase III trial of intraperitoneal Yttrium-90-labeled HMFG1 murine monoclonal antibody therapy. The capture antibody of these 2 assays was the murine antibody HMFG1, while mouse anti-human IgM-HRP or mouse anti-human IgG(Fc)-HRP served as tracer antibodies. A pool of HAMA-positive serum samples was used to prepare a series of assay standards and another pool served as reference preparation. The analytical sensitivity of the HAMA-IgM assay was 2.5 arbitrary units per mL (AU/mL) and 4.7 AU/mL for the HAMA-IgG ELISA. Diluted serum samples showed good parallelism with the HAMA-IgM and HAMA-IgG standard dose-response curves. Within-assay coefficient of variation was 7.5% for HAMA-IgM and 6.5% for HAMA-IgG. Between-assay variation was 14.2% for HAMA-IgM and 15.3% for HAMA-IgG. The developed HAMA-IgM and HAMA-IgG ELISAs show satisfactory reliability criteria (sensitivity, parallelism and precision) and are suitable for monitoring of HAMA-IgM and HAMA-IgG responses in ovarian cancer patients. These ELISAs will be used to monitor the development of HAMAs in patients who received radioimmunotherapy with murine HMFG1.

Key concepts: Antibody, Coefficient of variation, Radioimmunotherapy, Immunoglobulin M, Monoclonal antibody, Immunoglobulin G, Immunology, Biology

Related papers

Back to paper searchBrowse research topicsOriginal source
Development of ELISAs for Quantification of HMFG1-Specific Human Anti-Mouse IgG and IgM Antibodies — Research Paper | ScholarLens