2003•Unpublished venueRequires access

Specifying current limiting fuses to protect molded case circuit breakers

S. Schaffer

Open publisher page 1 citations

Abstract

In many industrial and commercial installations, electrical distribution systems can deliver short-circuit currents approaching 200000 A, RMS symmetrical. The overcurrent protective device must safely interrupt any overload or short circuit and protect the electrical components from damage and/or destruction. The factors involved in protecting molded-case circuit breakers applied beyond their withstand ratings are presented, and engineering solutions to the problem are provided. The focus is on modern current-limiting fuses. It is shown that actual molded-case circuit breaker withstand ratings can be significantly less than the marked interrupting ratings. Proper, safe applications would require the designer to be aware of these reduced ratings and design systems based on these values. When current-limiting fuses are used to protect circuit breakers, the I/sub p/ let-through of the fuse should be less than I/sub p/ withstand ratings of the circuit breaker. When molded-case circuit breakers are used, safe design practice dictates that the short circuit and power factor not exceed the tested values as determined by the UL test circuit.>

About this research paper

What this paper is about

In many industrial and commercial installations, electrical distribution systems can deliver short-circuit currents approaching 200000 A, RMS symmetrical. The overcurrent protective device must safely interrupt any overload or short circuit and protect the electrical components from damage and/or destruction. The factors involved in protecting molded-case circuit breakers applied beyond their withstand ratings are presented, and engineering solutions to the problem are provided. The focus is on modern current-limiting fuses. It is shown that actual molded-case circuit breaker withstand ratings can be significantly less than the marked interrupting ratings. Proper, safe applications would require the designer to be aware of these reduced ratings and design systems based on these values. When current-limiting fuses are used to protect circuit breakers, the I/sub p/ let-through of the fuse should be less than I/sub p/ withstand ratings of the circuit breaker. When molded-case circuit breakers are used, safe design practice dictates that the short circuit and power factor not exceed the tested values as determined by the UL test circuit.>

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In many industrial and commercial installations, electrical distribution systems can deliver short-circuit currents approaching 200000 A, RMS symmetrical. The overcurrent protective device must safely interrupt any overload or short circuit and protect the electrical components from damage and/or destruction. The factors involved in protecting molded-case circuit breakers applied beyond their withstand ratings are presented, and engineering solutions to the problem are provided. The focus is on modern current-limiting fuses. It is shown that actual molded-case circuit breaker withstand ratings can be significantly less than the marked interrupting ratings. Proper, safe applications would require the designer to be aware of these reduced ratings and design systems based on these values. When current-limiting fuses are used to protect circuit breakers, the I/sub p/ let-through of the fuse should be less than I/sub p/ withstand ratings of the circuit breaker. When molded-case circuit breakers are used, safe design practice dictates that the short circuit and power factor not exceed the tested values as determined by the UL test circuit.>

Key concepts: Circuit breaker, Fuse (electrical), Overcurrent, Sulfur hexafluoride circuit breaker, Distribution board, Current limiting, Limiting, Interrupt

Related papers

Back to paper searchBrowse research topicsOriginal source
Specifying current limiting fuses to protect molded case circuit breakers — Research Paper | ScholarLens