1996IEEE Transactions on Industry ApplicationsRequires access

An innovative method of providing total breaker failure protection

N.T. Stringer, D.L. Waser

Open publisher page 15 citations

Abstract

Circuit breaker failure relaying has been generally achieved through the use of a current monitoring relay to determine whether current continues to flow into a fault after a breaker has been instructed to interrupt the circuit. If current continues to flow after a predefined period of time, the circuit breaker is considered to have failed. Steps must then be taken to trip the next set of upstream breakers in the power system to remove the faulted circuit and prevent system damage. However, with industrial power systems, this may be the electric utility's breakers on the feeding transmission line. Regardless, breaker failure schemes must be designed to isolate both the faulted circuit and the failed circuit breaker. This paper discusses a new and innovative method of protecting circuit breakers from the failure described above, plus other failures that go unprotected with conventional schemes, thus providing "total" breaker failure protection.

About this research paper

What this paper is about

Circuit breaker failure relaying has been generally achieved through the use of a current monitoring relay to determine whether current continues to flow into a fault after a breaker has been instructed to interrupt the circuit. If current continues to flow after a predefined period of time, the circuit breaker is considered to have failed. Steps must then be taken to trip the next set of upstream breakers in the power system to remove the faulted circuit and prevent system damage. However, with industrial power systems, this may be the electric utility's breakers on the feeding transmission line. Regardless, breaker failure schemes must be designed to isolate both the faulted circuit and the failed circuit breaker. This paper discusses a new and innovative method of protecting circuit breakers from the failure described above, plus other failures that go unprotected with conventional schemes, thus providing "total" breaker failure protection.

Why it matters

OpenAlex reports 15 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Circuit breaker failure relaying has been generally achieved through the use of a current monitoring relay to determine whether current continues to flow into a fault after a breaker has been instructed to interrupt the circuit. If current continues to flow after a predefined period of time, the circuit breaker is considered to have failed. Steps must then be taken to trip the next set of upstream breakers in the power system to remove the faulted circuit and prevent system damage. However, with industrial power systems, this may be the electric utility's breakers on the feeding transmission line. Regardless, breaker failure schemes must be designed to isolate both the faulted circuit and the failed circuit breaker. This paper discusses a new and innovative method of protecting circuit breakers from the failure described above, plus other failures that go unprotected with conventional schemes, thus providing "total" breaker failure protection.

Key concepts: Circuit breaker, Transient recovery voltage, Distribution board, Interrupt, Residual-current device, Prospective short circuit current, Sulfur hexafluoride circuit breaker, Fuse (electrical)

Related papers

Back to paper searchBrowse research topicsOriginal source
An innovative method of providing total breaker failure protection — Research Paper | ScholarLens